Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty.
نویسندگان
چکیده
Alterations in bone strain as a result of implantation may contribute towards periprosthetic bone density changes after total hip arthroplasty. Computational models provide full-field strain predictions in implant-bone constructs; however, these predictions should be verified using experimental models wherever it is possible. In this work, finite element predictions of surface strains in intact and implanted composite femurs were verified using digital image correlation. Relationships were sought between post-implantation strain states across seven defined Gruen zones and clinically observed longer-term bone density changes. Computational predictions of strain distributions in intact and implanted femurs were compared to digital image correlation measurements in two regions of interest. Regression analyses indicated a strong linear correlation between measurements and predictions (R = 0.927 intact, 0.926 implanted) with low standard error (standard error = 38 µε intact, 26 µε implanted). Pre- to post-operative changes in measured and predicted surface strains were found to relate qualitatively to clinically observed volumetric bone density changes across seven Gruen zones: marked proximal bone density loss corresponded with a 50%-64% drop in surface strain, and slight distal density changes corresponded with 4%-14% strain increase. These results support the use of digital image correlation as a pre-clinical tool for predicting post-implantation strain shielding, indicative of long-term bone adaptations.
منابع مشابه
Bone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملStress shielding effects of two prosthetic groups after total hip joint simulation replacement
OBJECTIVE The study aims to compare the stress shielding effects of implantable anatomical and traditional prostheses after in vitro total hip joint replacement simulation. The study serves as a biomechanical basis for novel artificial prostheses and for clinical hip joint replacements. METHODS Sixteen femoral specimens from adult male corpses were randomly divided into two groups: the tradit...
متن کاملExperimental evaluation of new concepts in hip arthroplasty.
In this thesis we evaluated two different hip arthroplasty concepts trough in vitro studies and numerical analyses. The cortical strains in the femoral neck area were increased by 10 to 15 % after insertion of a resurfacing femoral component compared to values of the intact femur, shown in an in vitro study on human cadaver femurs. There is an increased risk of femoral neck fracture after hip r...
متن کاملStress Evaluation of Lower Limbs with Hip Osteoarthritis and Hip Arthroplasty
Stress shielding and bone remodeling effects are critical issues in promoting long term stability of Total Hip Arthroplasty (THA). Stress shielding occurs when the femur experiences less stress after the presence of the prosthesis stem. In this study, biomechanical evaluations of lower limbs are established using the finite element method in corresponding to stress distributions. Lower limbs CT...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
دوره 229 8 شماره
صفحات -
تاریخ انتشار 2015