Anticoagulation of Pregnant Women With Mechanical Heart Valves

نویسنده

  • Jeffrey S. Ginsberg
چکیده

T he management of pregnant women with mechanical heart valves is challenging. Recently, based on small numbers of patients and poor-quality data, correspondence from Aventis Pharmaceuticals Inc has described treatment “failures” and concerns about teratogenicity with the use of the low-molecular-weight heparin (LMWH) enoxaparin. The company issued a “Warning” that enoxaparin should not be used in patients with prosthetic heart valves and a “Precaution” about potential teratogenicity. This has created a huge problem for physicians managing pregnant women with prosthetic heart valves because the alternatives, unfractionated heparin and warfarin, are problematic. There have been case reports of failures (including death from thrombosed valves) with unfractionated heparin, whereas the package insert for warfarin states that the drug is contraindicated during pregnancy because of potential teratogenicity. Initially, LMWHs appeared suitable for pregnant patients with prosthetic heart valves. Unfortunately, the company correspondence, presumably supported by the Food and Drug Administration (FDA), raises medicolegal concerns with use of any LMWH. We believe that pharmaceutical companies and the FDA should not endorse scientifically unsupported claims that eliminate acceptable therapeutic options. This correspondence has created considerable confusion among patients and treating physicians and is likely to lead to frivolous lawsuits and preclude the performance of properly designed trials in pregnant women. We believe a consensus conference among experts in the field to identify key unresolved issues and a commitment by the FDA and industry to perform appropriate studies are now critical. Arch Intern Med. 2003;163:694-698

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An audit of pregnant women with prosthetic heart valves at a tertiary hospital in South Africa: a five-year experience

BACKGROUND Cardiac disease in pregnancy is a common problem in under-resourced countries and a significant cause of maternal morbidity and mortality. A large proportion of patients with cardiac disease have prosthetic mechanical heart valve replacements, warranting prophylactic anticoagulation. AIM To evaluate obstetric outcomes in women with prosthetic heart valves in an under-resourced coun...

متن کامل

Anticoagulation in pregnant women with prosthetic heart valves.

The combination of heart disease and pregnancy can present a formidable challenge to the clinician entrusted to care for both the mother and fetus. Since most data is retrospective, a definitive prognosis for such a patient may be difficult to obtain. Nevertheless, certain cardiac conditions carry greater risks of maternal mortality than do others. However, even for certain preexisting conditio...

متن کامل

Antithrombotic Management of Patients with Prosthetic Heart Valves.

Valvular heart disease is a major public health issue. The prevalence of valvular heart disease is expected to increase due to an aging population. Valve dysfunction manifests as valve stenosis, regurgitation, or both, due to various etiologies. Valve repair and replacement are the main treatment options for severe valve dysfunction. Valve replacement is achieved by using either a mechanical or...

متن کامل

Recommendations for the anticoagulation of pregnant patients with mechanical heart valves.

BACKGROUND The management of pregnant patients with mechanical heart valves remains challenging because there are no large randomised studies to provide guidelines for effective anticoagulant therapy. Both vitamin K antagonists and heparins may be associated with maternal and foetal adverse events. METHOD The Southern African Society of Thrombosis and Haemostasis reviewed available literature...

متن کامل

Anticoagulation of pregnant women with mechanical heart valves using low-molecular-weight heparin.

The management of pregnant women with mechanical heart valves is challenging. Recently, based on small numbers of patients and poor-quality data, correspondence from Aventis Pharmaceuticals Inc has described treatment "failures" and concerns about teratogenicity with the use of the low-molecular-weight heparin (LMWH) enoxaparin. The company issued a "Warning" that enoxaparin should not be used ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003