A novel approach to mammographic breast compression: Improved standardization and reduced discomfort by controlling pressure instead of force.
نویسندگان
چکیده
PURPOSE In x-ray mammography, flattening of the breast improves image quality and reduces absorbed dose. Current mammographic compression guidelines are based on applying a standardized force to each breast. Because breast size is not taken into consideration, this approach leads to large variations in applied pressure (force applied per unit contact area). It is the authors' hypothesis that a pressure-controlled compression protocol, which takes contact area into account, (1) improves standardization across the population in terms of physiological conditions in the compressed breast (blood pressure), and (2) reduces discomfort and pain, particularly the number of severe pain complaints, (3) with limited effects on image quality and absorbed glandular dose (AGD). METHODS A prospective observational study including 291 craniocaudal (CC) and 299 mediolateral oblique (MLO) breast compressions in 196 women following the authors' hospital's standard compression protocol with 18 decanewton (daN) target force was performed. Breast thickness, applied force, area of contact between breast and compression paddle, and mean pressure were recorded during the entire compression. Pain scores before and after breast compressions were obtained using an 11-point numerical rating scale (NRS). Scores of 7 and higher were considered to indicate severe pain. The authors analyzed differences between the CC and MLO compressions, correlation coefficients (ρ) between compression parameters, and odds-ratios (OR) for all parameters as possible predictors for experiencing severe pain using multivariate logistic regression. The observed data were used in two models to estimate what breast thickness, required force, and pain score would be for pressure-controlled compression protocols with target pressures ranging from 4 to 28 kilopascal (kPa). For a selection of 79 mammograms having a 10% or more thickness difference with respect to the prior mammogram, the authors performed a retrospective observer study to assess whether such thickness differences have significant effects on image quality or AGD. RESULTS In a standard 18 daN force-controlled compression protocol, the authors observed an average pressure of 21.3 kPa±54% standard deviation for CC compressions and 14.2 kPa±32% for MLO compressions. Women with smaller breasts endured higher pressures and experienced more pain, as indicated by a significant negative correlation (ρ=-0.19, p<0.01) between contact area and pain score. Multivariate regression showed that contact area is a strong and significant predictor for severe pain (ORNRS≥7 (CC)=0.10/dm2, p<0.05), as is the case with any pain already present before compression (ORNRS≥7 (CC)=1.61 per NRS-point, p<0.05). Model estimations showed that mammographic breast compression with a standardized pressure of 10 kPa, corresponding with normal arterial blood pressure, may significantly reduce the number of severe pain complaints with an average increase in breast thickness of 9% for small breasts and 2% for large breasts. For an average 16.5% thickness difference in prior-current mammogram pairs, the authors found no differences in image quality and AGD CONCLUSIONS: Model estimations and an observer study showed that pressure-controlled mammographic compression protocols may improve standardization and reduce discomfort with limited effects on image quality and AGD.
منابع مشابه
Mammographic compression--a need for mechanical standardization.
BACKGROUND A lack of consistent guidelines regarding mammographic compression has led to wide variation in its technical execution. Breast compression is accomplished by means of a compression paddle, resulting in a certain contact area between the paddle and the breast. This procedure is associated with varying levels of discomfort or pain. On current mammography systems, the only mechanical p...
متن کاملImprovement of Breast Cancer Detection Using Non-subsampled Contourlet Transform and Super-Resolution Technique in Mammographic Images
Introduction Breast cancer is one of the most life-threatening conditions among women. Early detection of this disease is the only way to reduce the associated mortality rate. Mammography is a standard method for the early detection of breast cancer. Today, considering the importance of breast cancer detection, computer-aided detection techniques have been employed to increase the quality of ma...
متن کاملMammographic compression in Asian women
OBJECTIVES To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. METHODS We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammograp...
متن کاملPatient comfort from the technologist perspective: factors to consider in mammographic imaging
A sample size of 280 certified mammography technologists were surveyed to understand what factors affect patient discomfort during breast imaging. Given mammography technologists' level of patient involvement, they are uniquely positioned to observe factors that affect patient comfort. The findings suggest that according to technologists, multiple factors, including patient ethnicity, breast de...
متن کاملبررسی نقش سونوگرافی تکمیلی در تشخیص سرطان پستان
Introduction & Objective: The breast cancer is the most common malignancy in women and in recent years it is seen in younger ages. Because of dense breast tissue in these ages, the mammography sensitivity for breast cancer detection is reduced, so high quality ultrasonography (US) as a combined screening method is effective. The aim of this study is the evaluation of the mammographic finding ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 40 8 شماره
صفحات -