On the Photometric Accuracy of RHESSI Imaging and Spectrosocopy
نویسندگان
چکیده
We compare the photometric accuracy of spectra and images in flares observed with theRamaty High Energy Solar Spectroscopic Imager (RHESSI) spacecraft. We test the accuracy of the photometry by comparing the photon fluxes obtained in different energy ranges from the spectral-fitting software SPEX with those fluxes contained in the images reconstructed with the Clean, MEM, MEMVis, Pixon, and Forward-fit algorithms. We quantify also the background fluxes, the fidelity of source geometries, and spatial spectra reconstructed with the five image reconstruction algorithms. We investigate the effects of grid selection, pixel size, field-of-view, and time intervals on the quality of image reconstruction. The detailed parameters and statistics are provided in an accompanying CD-ROM and web page. We find that Forward-fit, Pixon, and Clean have a robust convergence behavior and a photometric accuracy in the order of a few percents, while MEM does not converge optimally for large degrees of freedom (for large field-of-views and/or small pixel sizes), and MEM-Vis suffers in the case of time-variable sources. This comparative study documents the current status of the RHESSI spectral and imaging software, one year after launch.
منابع مشابه
Use of imaging techniques in detection of parotid masses Location compared to surgery
Objective: The purpose of this study was to compare the use of cross-sectional imaging techniques verses surgery in locating parotid masses. Material and Methods: Our study was performed on patients assumed to have parotid masses from Dec 2010 to Dec 2011. Before surgery, imaging studies (Computed Tomography and Magnetic Resonance Imaging) of parotid were done. After surgery, we compared the s...
متن کاملRHESSI Imager and Aspect Systems
RHESSI uses nine Rotating Modulation Collimators (RMCs) for imaging, each consisting of a pair of grids mounted on the rotating spacecraft. The angular resolutions range from 2.3 arcsec to 3arcmin. The relative twist between the two grids of each pair is the most critical parameter. It must be less than 20 arcsec for the finest grid. After precision alignment, it is monitored by the Twist Monit...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملDetection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging
Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...
متن کامل