Computation of energy imparted in diagnostic radiology.

نویسندگان

  • N A Gkanatsios
  • W Huda
چکیده

Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z, were computed for x-ray spectra with peak x-ray tube voltages ranging from 50-140 kV and with added filtration, ranging from 1-6 mm aluminum. For a given phantom thickness and peak x-ray tube voltage, the energy imparted was found to be directly proportional to the x-ray beam half-value layer (HVL) expressed in millimeters of aluminum. Values of omega (z) were generated for constant waveform x-ray tube voltages and an anode angle of 12 degrees, and were fitted to the expression omega (z) = alpha x HVL + beta. Fitted alpha and beta parameters are provided that permit the energy imparted to be determined for any combination of tube voltage, half-value layer, and phantom thickness from the product of the entrance skin exposure (free-in-air) and the corresponding x-ray beam area. The results obtained using our method for calculating energy imparted were compared with values of energy imparted determined using Monte Carlo techniques and anthropomorphic phantoms for a range of diagnostic examinations. At 60, 80, and 120 kV, absolute values of energy imparted obtained using our method differed by 8%, 10%, and 12%, respectively, from the corresponding results of Monte Carlo computations obtained for an anthropomorphic phantom. The method described in this paper permits a simple determination of energy imparted for any type of diagnostic x-ray examination which may be used to compare the radiologic risks from differing types of x-ray examinations, optimize imaging techniques with respect to the patient dose, or estimate the patient effective dose equivalent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent convention...

متن کامل

Effective dose and energy imparted in diagnostic radiology.

The patient effective dose, E, is an indicator of the stochastic radiation risk associated with radiographic or fluoroscopic x-ray examinations. Determining effective doses for radiologic examinations by measurement or calculation is generally very difficult. By contrast, the energy imparted, epsilon, to the patient may be obtained from the x-ray exposure-area product incident on the patient. A...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Adult patient doses in interventional neuroradiology.

We investigated radiation doses to 149 adult patients who underwent interventional neuroradiologic procedures, consisting of 132 patients who had diagnostic imaging examinations and 17 patients who had therapeutic procedures. The interventional procedures were carried out on a biplane system capable of performing fluoroscopy and digital subtraction angiography (DSA). The x-ray imaging system wa...

متن کامل

Investigating the effect of voltage fluctuations on the beam quality of X-rays in the range energy of diagnostic radiology

The purpose of this study was to investigate the effect of voltage ripple produced by X-ray machines on the quality of X-ray rays. For this purpose, the energy spectrum from the X-ray tube manufacturer should be simulated in the range of diagnostic radiography and verified by experimental results. The statistical analysis of the results showed that there is no significant difference between sim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 1997