Lumen reduction measurements of the internal carotid artery before and after Levovist enhancement: reproducibility and agreement with angiography.

نویسندگان

  • O E Elgersma
  • M S van Leeuwen
  • R Meijer
  • B C Eikelboom
  • Y van der Graaf
چکیده

Our aim was to assess reproducibility of three different lumen reduction measuring methods--North American Symptomatic Carotid Endarterectomy Trial, European Carotid Surgery Trial, and common carotid--using power Doppler and color Doppler sonography before and after Levovist enhancement. We included 20 symptomatic patients with mild or severe carotid disease. North American Symptomatic Carotid Endarterectomy Trial, European Carotid Surgery Trial, and common carotid measurements on longitudinal views and European Carotid Surgery Trial measurements on transverse views were performed. Examinations were repeated and the results compared to assess reproducibility of measurements. Correlation with angiography was obtained by calculating Pearson correlation coefficients. Reproducibility was significantly better (P < 0.05) for European Carotid Surgery Trial and common carotid measurements (95% limits of agreement between -10% to 10% and -19% to 17%) as compared to North American Symptomatic Carotid Endarterectomy Trial measurements (95% limits of agreement between -11% to 21% and -21% to 23%). Variability of measurements after enhancement increased slightly (not significant) for both power and color Doppler sonography. Additionally, European Carotid Surgery Trial measurements, using nonenhanced power Doppler or color Doppler sonography, did not correlate significantly with angiography, whereas North American Symptomatic Carotid Endarterectomy Trial and common carotid measurements correlated well with angiography, particularly in power Doppler mode after enhancement (r = 0.88 and r = 0.82, respectively). We conclude that for lumen reduction measurements of the internal carotid artery with power and color Doppler sonography, the common carotid method is the only method that is reproducible and has good correlation with angiography, which slightly improves after Levovist enhancement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decreased Intima-Media Carotid Artery Thickness after 24 Sessions of Combined Aerobic and Resistance Exercise in Type 2 Diabetic Patients

Background and Objective: Diabetes type 2 has been estimated as the seventh leading cause of death worldwide. Diabetic patients are 2-3 times more likely to be at the risk of atherosclerosis, compared to normal people. It has been reported that exercise prevents atherosclerosis in diabetic patients. Therefore, the aim of this study was to investigate the effect of exercise on vascular variables...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

High-Grade Internal Carotid Stenosis With Color Doppler-Assisted Duplex Imaging

Background and Purpose The remaining limitations of ultrasonographic imaging in accurately quantifying internal carotid stenosis or diagnosing internal carotid occlusion may be overcome by enhancing the echogenicity of flowing arterial blood with contrast agents. This study assessed the usefulness of the intravenous (transpulmonary) contrast medium SH U 508 A in improving the characterization a...

متن کامل

Usefulness of an intravenous contrast medium in the characterization of high-grade internal carotid stenosis with color Doppler-assisted duplex imaging.

BACKGROUND AND PURPOSE The remaining limitations of ultrasonographic imaging in accurately quantifying internal carotid stenosis or diagnosing internal carotid occlusion may be overcome by enhancing the echogenicity of flowing arterial blood with contrast agents. This study assessed the usefulness of the intravenous (transpulmonary) contrast medium SH U 508 A in improving the characterization a...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1999