Arthroscopic evaluation for omalgia patients undergoing the clavicular hook plate fixation of distal clavicle fractures
نویسندگان
چکیده
BACKGROUND The aim of this study is to investigate the anatomic changes in the shoulder joints responsible for omalgia after the clavicular hook plate fixation under arthroscope. METHODS Arthroscopic examination was carried out for 12 omalgia patients who underwent clavicular hook plate fixation due to distal clavicle fractures. Functional outcome of shoulder was measured by the Japanese Orthopaedic Association (JOA) score before and after the withdrawal of the fixation plate. RESULTS The rotator cuff compression by the clavicular hook was arthroscopically observed in 11 of the 12 cases. The JOA scores of the shoulder were significantly improved at 1 month after the withdrawal of the fixation plate (pain, 28 ± 2.4 vs. 15 ± 5.2; function, 19.2 ± 1.0 vs. 11.7 ± 1.9; range of movements, 26.8 ± 2.6 vs. 14.8 ± 3.4) compared with before. CONCLUSIONS The impingement of the hook to the rotator cuff may be the main cause for the omalgia. The appropriate hook and plate that fit to the curve of the clavicle as well as the acromion are necessary to decrease the severity of omalgia.
منابع مشابه
Clinical results of treatment using a clavicular hook plate versus a T-plate in neer type II distal clavicle fractures.
AO clavicular hook plate fixation provides more rigid fixation and good bony union rates for Neer type II distal clavicular fractures. However, the hook may cause rotator cuff tears and subacromial impingement, which adversely affect the clinical results. T-plate fixation is another surgical method of treatment for unstable clavicle fractures, and its clinical efficacy has been demonstrated. Th...
متن کاملSurgical treatment of Neer type-II fractures of the distal clavicle A meta-analysis
Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. DOI 10.3109/17453674.2013.786637 Background and purpose Type-II distal clavicle fractures according to the Neer classification are generally operated because of the hi...
متن کاملComparing hook plates and Kirschner tension band wiring for unstable lateral clavicle fractures.
The purpose of this study was to compare outcomes and complications of clavicular hook plate and Kirschner tension band wiring for fixation of unstable lateral clavicle fractures. The surgical outcomes of 92 consecutive patients (mean age, 49.30 ± 15.54 years) with unstable fractures of the lateral clavicle treated using AO clavicle hook plates were compared with those of 24 patients (mean age,...
متن کاملSurgical treatment of Neer type-II fractures of the distal clavicle
BACKGROUND AND PURPOSE Type-II distal clavicle fractures according to the Neer classification are generally operated because of the high non-union rate after non-operative treatment. Several surgical techniques have been developed in order to reduce the non-union rate and improve functional outcome. This meta-analysis overviews the available surgical techniques for type-II distal clavicular fra...
متن کاملClavicular Hook Plate: A Better Implant Choice for Fixation of Unstable Distal Clavicle Fractures?
1878-3317/$ e see front matter Copyright 2012, Ta http://dx.doi.org/10.1016/j.jecm.2012.09.002 Background: The ideal fixation method for unstable distal clavicle fractures is still controversial. Clavicular hook plates (HPs) are an effective option but the clinical efficacy and advantages/disadvantages of this implant compared with the tension band wire technique in treating this fracture have ...
متن کامل