Limited dynamic range of a new assay for serum folate.
نویسندگان
چکیده
To the Editor: Recently, several new nonisotopic protein-binding folate assays have become available. We have studied the AxSYM folate assay (Abbott Laboratories , Abbott Park, IL), in which folate is quantified by measurement of unoccupied binding sites on the folate-binding protein (1). The cali-brators for the assay cover the range 0 – 45 nmol/L. In the absence of an internationally accepted reference method or material (2), we have compared the performance of the AxSYM method with two methods commonly used nationally and internationally, namely the SimulTrac-SNB (ICN Fig. 1. Comparison of results for 100 serum folate samples. (A), AxSYM folate assay vs Quantaphase II folate assay (y ϭ 0.63x ϩ 2.8 nmol/L; r ϭ 0.824; n ϭ 100). (B), difference of AxSYM and Quantaphase II folate plotted against the average of AxSYM and Quantaphase II folate; horizontal lines are the mean bias (⅐ ⅐ ⅐ ⅐ ⅐) and Ϯ 2 SD values (Ϫ ⅐ Ϫ ⅐ Ϫ ⅐ Ϫ). (C), AxSYM folate assay vs SimulTrac folate assay (y ϭ 0.58x ϩ 2.7 nmol/L; r ϭ 0.823; n ϭ 100). (D), difference of AxSYM and SimulTrac folate plotted against the average of AxSYM and SimulTrac folate; 1, patients with renal failure. (E), linearity study; (——), least-squares linear regression line for the points at 10 –30% high sample.
منابع مشابه
Automation and Analytical Techniques: Measurement of Folate in Fresh and Archival Serum Samples as p-Aminobenzoylglutamate Equivalents
RESULTS: The limit of quantification was 0.25 nmol/L, and the assay was linear in the range 0.25–96 nmol/L, which includes the 99.75 percentile for serum folate concentrations in healthy blood donors. Withinand between-day imprecision was 5%. We detected no residual folate in serum samples after sample preparation. Folate concentrations in fresh serum samples obtained with the pABG assay and wi...
متن کاملMeasurement of folate in fresh and archival serum samples as p-aminobenzoylglutamate equivalents.
BACKGROUND The development of accurate and precise folate assays has been difficult, mainly because of folate instability. Large interassay and interlaboratory differences have been reported. We therefore developed a serum folate assay that measures folate and putative degradation products as p-aminobenzoylglutamate (pABG) equivalents following oxidation and acid hydrolysis. METHODS Serum was...
متن کاملResults with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood.
We compared results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested...
متن کاملBlood folate concentrations analyzed by microbiological assay and chemiluminescent immunoassay methods.
A limited number of studies have been available to compare blood folate concentrations by the microbiological assay (MA) method with those using the chemiluminescent immunoassay (CLIA) method. We compared folate concentrations measured by Lactobacillus rhamnosus MA with those measured by CLIA (Access Immunoassay Systems) in human plasma/serum and erythrocytes pairs (n=35). The mean plasma folat...
متن کاملExperience with microbiological assay for folate using a chloramphenicol-resistant L. casei strain.
Experience with a semi-automated L. casei folate assay using a chloramphenicol-resistant strain of organism is described. Control of pH of medium and incubation time was required. The normal range for serum folate was 2 to 16 ng/ml and red cell folate 200 to 600 ng/ml.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 45 4 شماره
صفحات -
تاریخ انتشار 1999