Ferrite-guided cyclotron-resonance maser.

نویسندگان

  • Eli Jerby
  • A Kesar
  • A Aharony
  • G Breitmeier
چکیده

The concept of a cyclotron-resonance maser (CRM) with a ferrite loading incorporated in its waveguide is proposed. The CRM interaction occurs between the rotating electron beam and the em wave propagating along a longitudinally magnetized ferrite medium. The ferrite anisotropic permeability resembles the CRM susceptibility in many aspects, and particularly in their similar response to the axial magnetic field (the ferrite susceptibility can be regarded as a passive analog of the active CRM interaction). The ferrite loading slows down the phase velocity of the em wave and thus the axial (Weibel) mechanism of the CRM interaction dominates. The ferrite loading enables also a mechanism of spectral tunability for CRM's. The ferrite loading is proposed, therefore, as a useful ingredient for high-power CRM devices. A linear model of the combined ferrite-guided CRM interaction reveals its useful features. Future schemes may also incorporate ferrite sections functioning as isolators, gyrators, or phase shifters within the CRM device itself for selective suppression of backward waves and spurious oscillations, and for gain and efficiency enhancement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pfc/ja-85-4 Free Electron Laser or Cyclotron Maser Instability?

An analysis of recent free electron laser experiments in combined wiggler and strong axial magnetic fields shows that near resonance, Q,,=kwv,,, the proximity of the cyclotron maser instability precludes an unambiguous identification of the radiation mechanism ( 2,, is the cyclotron frequency in the axial field, kw is the wiggler wavenumber, and v,, the axial electron velocity).

متن کامل

Cyclotron-resonance maser in a periodically loaded quadrupole transmission line.

A cyclotron-resonance maser (CRM) is implemented in a periodic quadrupole waveguide. The device oscillates at the fundamental and high harmonics of the cyclotron frequency. This CRM employs a tenuous low-energy electron beam ( approximately 10 keV, 0.2 A). The periodic structure consists of an array of disks along the quadrupole transmission line, hence it combines both azimuthal and axial peri...

متن کامل

Cyclotron-resonance maser in a magnetic mirror.

A cyclotron-resonance maser (CRM) experiment is performed in a high-gradient magnetic field using a low-energy electron beam ( approximately 10 keV/1 A). The magnetic field exceeds 1.63 T, which corresponds to a 45-GHz cyclotron frequency. The CRM radiation output is observed in much lower frequencies, between 6.6 and 20 GHz only. This discrepancy is explained by the finite penetration depth of...

متن کامل

Theory of the anomalous Doppler cyclotron-resonance-maser amplifier with tapered parameters

The theory of a slow-wave cyclotron-resonance-maser ~CRM! amplifier employing an initially linear electron beam is developed. In such a device, the electrons radiate electromagnetic waves under the anomalous Doppler effect. In order to maintain the cyclotron resonance between the radiating electrons and the amplifying electromagnetic wave, we consider a system with tapered waveguide parameters....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 65 6 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2002