Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing corneal aberration of normal and abnormal eyes.

نویسندگان

  • Geunyoung Yoon
  • Seth Pantanelli
  • Scott MacRae
چکیده

PURPOSE To investigate the accuracy of Zernike and Fourier reconstruction algorithms in describing simulated wavefront data from corneal topography of normal and abnormal eyes. METHODS Corneal topography (Orbscan Ilz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 postoperative LASIK symptomatic eyes over a 6-mm pupil. Raw data from slit images were converted into elevation maps, which were then resampled at resolutions of 100, 300, and 500 microm. Differences in elevation between adjacent pixels were used to generate simulated wavefront slope data. Both conventional Zernike and iterative Fourier algorithms were used to reconstruct the elevation map from the same slope information. The difference between the reconstructed and original maps was used to evaluate reconstruction performance, quantified by the residual root-mean-square (RMS) error. RESULTS When using the Zernike-based method, residual RMS error decreased substantially as the number of modes used in the reconstruction increased up to approximately the 10th order. Both Zernike and Fourier algorithms performed best when reconstructing simulated wavefronts from normal eyes and worst with PKP eyes. Using a large number of Zernike modes to reconstruct simulated wavefronts of low spatial resolution lead to inaccurate reconstructions. The Fourier method had better reconstruction reliability in the center of the pupil than peripherally. Only 2nd through 5th order Zernike modes were required to produce less residual RMS error than the Fourier method. CONCLUSIONS For all conditions tested, the Zernike method outperformed the Fourier method when representing simulated wavefront data from topography maps. Even 2nd through 5th order Zernike polynomials were enough to outperform the Fourier method in all populations. Up to 9th order Zernike modes may be required to accurately describe the simulated wavefronts in some abnormal eyes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing the corneal aberration of normal and abnormal eyes

Purpose: The goal of this study was to investigate with what accuracy the Zernike and Fourier reconstruction algorithms can describe the corneal aberration in normal and abnormal eyes. Methods: Corneal topography (Orbscan IIz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 post-LASIK symptomatic eyes. Raw topography images were converted into elevation maps...

متن کامل

Apparent accommodation and corneal wavefront aberration in pseudophakic eyes.

PURPOSE To assess the relationship between apparent accommodation in pseudophakic eyes, multifocal corneal effects, and wavefront aberrations of the cornea. METHODS In 102 eyes of 86 patients who had undergone phacoemulsification and posterior chamber intraocular lens implantation, the amount of apparent accommodation was measured with an accommodometer. The degree of corneal multifocality wa...

متن کامل

Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high-dynamic range wavefront sensor.

PURPOSE The purpose of this study was to characterize aberrations in 2 populations of eyes, namely those with keratoconus (KC) and those having undergone penetrating keratoplasty (PK), using a large-dynamic range Shack-Hartmann wavefront sensor. DESIGN Prospective comparative case series. PARTICIPANTS Twenty-one people with ocular pathologic features (either KC or PK) were recruited for thi...

متن کامل

Posterior corneal aberrations and their compensation effects on anterior corneal aberrations in keratoconic eyes.

PURPOSE To characterize posterior corneal aberrations in keratoconic (KC) eyes and investigate compensatory effects between anterior and posterior corneal surfaces. METHODS The corneal topography of 113 eyes (37 advanced KC, 31 moderate KC, 14 mild KC, and 31 normal eyes) was used to compute the corneal aberrations. The central 6-mm diameter of both anterior and posterior corneal topographies...

متن کامل

Wave aberration of human eyes and new descriptors of image optical quality and visual performance.

The expansion of wavefront-sensing techniques redefined the meaning of refractive error in clinical ophthalmology. Clinical aberrometers provide detailed measurements of the eye's wavefront aberration. The distribution and contribution of each higher-order aberration to the overall wavefront aberration in the individual eye can now be accurately determined and predicted. Using corneal or ocular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2008