Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.

نویسندگان

  • P Valta
  • J Takala
  • R Foster
  • C Weissman
  • J M Kinney
چکیده

STUDY OBJECTIVE To assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing. DESIGN An open comparison between two methods using a criterion standard. Either a pneumotachometer (mechanically ventilated patients) or a spirometer (spontaneously breathing subjects) was used as the reference method. SETTING Tertiary care center; a multidisciplinary intensive care unit and a metabolic research unit. PATIENTS Six mechanically ventilated, paralyzed postoperative open heart surgery patients, six spontaneously breathing COPD patients, and eight healthy volunteers. INTERVENTIONS Stepwise increases and reductions of PEEP from zero to 12 cm H2O during controlled mechanical ventilation; repeated validation of the calibration of the respiratory inductive plethysmography (RIP) in both mechanically ventilated and spontaneously breathing subjects. MEASUREMENTS AND RESULTS The baseline drift of the RIP in vitro was 10 ml/150 min and in a ventilated model it was 20 ml/150 min. In mechanically ventilated patients, the mean error of the calibration after 150 min was within +/- 5 percent. Change in end-expiratory lung volume (EELV) during the stepwise increase of PEEP up to 12 cm H2O was 849 +/- 136 ml with the RIP and 809 +/- 125 ml with the pneumotachometer (PT), and during the stepwise reduction of PEEP it was 845 +/- 124 ml and 922 +/- 122, respectively (not significant [NS]. The mean difference between methods in the measurement of change in EELV was -6.6 +/- 3.5 percent during increasing and 6.6 +/- 6.7 percent during decreasing PEEP (NS). Both in mechanically ventilated and spontaneously breathing subjects, the difference between methods was significant for VT and VT/TI. The difference in VT was -2.2 +/- 0.2 percent during mechanical ventilation, -1.1 +/- 0.5 percent in spontaneously breathing COPD patients, and 2.9 +/- 0.4 percent in healthy volunteers (NS between groups). CONCLUSIONS The RIP is sufficiently accurate for the measurement of PEEP-induced changes in EELV during controlled mechanical ventilation. The accuracy of tidal volume measurement is similar during mechanical ventilation and spontaneous breathing. The calibration of the RIP is stable enough for bedside monitoring of changes in lung volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory inductive plethysmography accuracy at varying PEEP levels and degrees of acute lung injury.

BACKGROUND AND OBJECTIVE This study was performed to assess the accuracy of respiratory inductive plethysmographic (RIP) estimated lung volume changes at varying positive end-expiratory pressures (PEEP) during different degrees of acute respiratory failure. METHODS Measurements of inspiratory tidal volume were validated in eight piglets during constant volume ventilation at incremental and de...

متن کامل

The Role of Rapid Shallow Breathing Index in Predicting Successful Weaning of Pediatric Patients with Respiratory Failure

Background About 40 to 60% of all patients admitted to pediatric intensive care unitsundergo mechanical ventilation and 10 to 20% will fail to be extubated. We aimed to determine the role of the rapid shallow breathing index (RSBI) in predicting successful weaning of pediatric patients with respiratory failure.   Materials and Methods: This cross-sectional study, was performed on 72 mechanical...

متن کامل

Effects of PEEP on respiratory mechanics after open heart surgery.

Respiratory dysfunction, particularly atelectasis, is common after open heart surgery. Routine use of PEEP (5 to 10 cm H2O) in these patients has been advocated. We studied the effects of different levels of PEEP on respiratory mechanics in ten mechanically ventilated open heart surgery patients in the immediate postoperative period. PEEP was studied in increasing increments and decreasing decr...

متن کامل

Pharmacokinetic Behavior of Theophylline following PEEP in Critically Ill Patients with Acute Lung Injury

The effect of Positive End Expiratory Pressure (PEEP) on the hepatic elimination of low to moderate extraction ratio drugs has not been clearly defined. We prospectively investigated the effect of PEEP on the clearance of theophylline in 30 (20 males and 10 females) intubated critically ill adult patients with acute lung injury/acute respiratory distress syndrome (ALI/ARDS). The Mean (±SD) age ...

متن کامل

Respiratory pattern of diaphragmatic breathing and pilates breathing in COPD subjects

BACKGROUND Diaphragmatic breathing (DB) is widely used in pulmonary rehabilitation (PR) of patients with chronic obstructive pulmonary disease (COPD), however it has been little studied in the scientific literature. The Pilates breathing (PB) method has also been used in the rehabilitation area and has been little studied in the scientific literature and in COPD. OBJECTIVES To compare ventila...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 1992