Catheter detachment.

نویسندگان

  • Takayo Ota
  • Hiroshi Tsukuda
  • Masahiro Tokunaga
  • Norifumi Nishida
  • Yoshikazu Hasegawa
  • Tomohiro Suzumura
  • Masahiro Fukuoka
چکیده

Catheter detachment Takayo Ota1,*, Hiroshi Tsukuda1, Masahiro Tokunaga2, Norifumi Nishida3, Yoshikazu Hasegawa1, Tomohiro Suzumura1, and Masahiro Fukuoka1 Department of Medical Oncology, Izumi Municipal Hospital, Izumi, Osaka, Japan, Department of Radiology, Izumi Municipal Hospital, Izumi, Osaka, Japan, and Department of Diagnostic and Interventional Radiology, Osaka City Medical University, Osaka, Japan

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Device malfunction in endovascular treatment of intracranial aneurysms: shared responsibilities of physician and manufacturer.

. . . the war is too important to leave it to the generals, the medicine is too important to leave it to the doctors, the science is too important to leave it to the scientist. . . In this issue of the AJNR, Kwon et al describe “technical problems associated with new designs of Guglielmi Detachable coil [GDC]”; namely, device malfunction, such as the spontaneous detachment of GDC coils, coil ba...

متن کامل

Marker alignment for Guglielmi detachable coil embolization: practical considerations.

BACKGROUND AND PURPOSE Aneurysm embolization is not without risk: numerous technical aspects are considered before, during, and after the procedure. The purpose of this study was to show the position of the detachment zone of a Guglielmi detachable coil (GDC) with respect to the catheter tip for various microcatheters and marker alignments. METHODS Six types of commonly used microcatheters we...

متن کامل

Liquid embolization of brain arteriovenous malformation using novel detachable tip micro catheter: a technical report.

BACKGROUND AND IMPORTANCE Liquid embolization using Onyx® of brain arteriovenous malformations (AVMs) is sometimes limited by micro catheter retention by Onyx® cast during the disengagement process. Use of the new detachable tip micro catheter is presented in this report. CLINICAL PRESENTATION Two feeding arteries of a previously ruptured brain AVM in a 62-year-old man were embolized by Onyx ...

متن کامل

Therapeutic embolization with a microballoon catheter system.

Clinical experience with a new embolization and perfusion microballoon catheter system is presented in 34 patients with angiomas, arteriovenous fistulas, and cerebral hemorrhages. The system uses two separate balloon tips, one for detachment as an embolus and one for perfusion of elastomer. The criteria for catheter and perfusate selection are described. One permanent complication, two temporar...

متن کامل

Results of treatment of arteriovenous fistulae with the Debrun technique.

In a series of 54 caroticocavernous fistulae and eight vertebrovertebral fistulae, clinical cures were obtained in 46 of the caroticocavernous fistulae and in all of the vertebrovertebral fistulae using the Debrun coaxial catheter detachable balloon technique. Most low vertebrovertebral and about half of the posteriorly opening caroticocavernous fistulae were successfully treated by the safe tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Oxford medical case reports

دوره 2015 5  شماره 

صفحات  -

تاریخ انتشار 2015