Mixed-phase Feeds in Mass Transfer Columns and Liquid Separation

نویسندگان

  • M. Wehrli
  • P. Schaeffer
  • U. Marti
  • F. Muggli
  • H. Kooijman
چکیده

The flashing feed sections of crude oil vacuum towers are especially prone to liquid entrainment. This can be detrimental to the performance of the packings/trays above the feed. It is also of disadvantage in case liquid is collected and recirculated back to the furnace. Therefore it is common practice to use special inlet devices that help preventing or minimizing liquid entrainment while maximizing the flash conditions. Such devices are also frequently used in gas/liquid separators. The similarity rules for the mixed-phase feed inlet are discussed and applied to a 1 m diameter air/water simulator that is used as a model for a crude oil vacuum tower of 5.25 m inner diameter. For a given inlet device the turbulent flow field of the dry vapour is fully determined by four essentially geometrical dimensionless parameters. The Froude number and the flow parameter account for the two-phase nature of the flow. Two devices with vanes (a short assembly and the modified Schoepentoeter inlet device) and a standard feed without any device are tested experimentally in the air/ water simulator. Their liquid disengaging capability is assessed by means of the entrainment rate. In the present installation the more complex device reaches virtually zero entrainment below a gas load factor of 0.08 m/s. The entrainment rate of both devices is fairly independent of the flow parameter while the standard feed shows more entrainment when the flow parameter is increased. Compared to the standard feed the short assembly improves only at the higher flow parameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Studies of Drop Behavior and Prediction of Sauter Mean Drop Diameter in Various Rotary Agitated Extraction Columns

Knowledge of droplet behavior is one of the most important criteria for determination of mass transfer kinetics for choosing the type of liquid-liquid extraction columns. Mean drop size data of dispersed phase droplets in continuous phase have been obtained for Various Rotary Agitated Liquid-Liquid Extraction Columns . The effects of operational variables such as mass transfer directions with a...

متن کامل

Investigation of mass transfer coefficients in irregular packed liquid-liquid extraction columns in the presence of various nanoparticles

In the present study, the effect of various nanofluids on mass transfer coefficients in an irregular packed liquid-liquid extraction column was investigated. The chemical system of toluene–acetic acid–water was used. 10 nm SiO2, TiO2 and ZrO2 nanoparticles with various concentrations were dispersed in toluene-acid acetic to provide nanofluids. The influence of concentration and hydrophobicity/h...

متن کامل

Mass Transfer Coefficients in Pulsed Column for Separation of Samarium and Gadolinium

The mass transfer performance of a pulsed disc and doughnut column for extraction of samarium and gadolinium from aqueous nitrate solution with D2EHPA was investigated. The effects of operating parameters such as pulsation intensity, continuous and dispersed phase velocities on column performance were investigated. The axial dispersion model was used to obtain the overall mass transfer coef...

متن کامل

Separation of Sedative – Hypnotic Drugs with Mixed Micellar Liquid Chromatography

Separation of ten sedative- hypnotic drugs was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, type and amount of organic modifier in mobile phase on efficiency (N) and asymmetry factor (B/A) showed that, the appropriate conditions for a good separation were 35°C and 7% (V/V) butanol in mobile phase.  Variations of selectivity factor versus butanol concent...

متن کامل

Stagewise Modeling of Liquid-Liquid Extraction Column (RDC)

Stagewise forward mixing model considering coalescence and redispersion of drops was used to predict the performance of Rotating Disc Liquid-Liquid Extraction Contactors. Experimental data previously obtained in two RDC columns of 7.62cm diameter, 73.6cm height and 21.9cm diameter, 150cm height were used to evaluate the model predictions. Drop-side mass transfer coefficients were predicted appl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006