Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran

نویسندگان

  • D. Khoshdel-Navi
  • A. Shabestani-Monfared
  • M. R. Deevband
  • R. Abdi
  • M. Nabahati
چکیده

BACKGROUND The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate. OBIECTIVE The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the most conventional x-ray examination. METHODS In this study, 13 public hospitals in Mazandaran province were selected for review and required data collected for ten adult patients with mean weight of 70±10kg in each projection. Then, information of each center was separately analyzed. Next, in order to measure x-ray output tube, the dosimeter RTI model Barracuda calibrated has been applied for measuring air karma within energy rage of 40-150kvp. ESAK and ESD parameters, usually used for monitoring DRL in conventional radiography, were calculated. RESULTS Mean ESDs in this study has been obtained to 1.47±0.98 for skull (PA/AP), 1.01±0.79 for skull (LAT), 0.67±0.38 for cervical spine (AP), 0.79±0.37 for cervical (LAT), 0.49±0.38 for chest (PA/AP), 1.06±0.44 for chest (LAT), 2.15±0.73 for thoracic spine (AP), 3±0.87 for thoracic spine (LAT), 2.81 ±0.82 for lumbar spine (AP), 4.28±0.78 for lumbar (LAT), 2.07±1.17 for abdomen and 1.90±0.99 for pelvis, respectively. The ESDs calculated for chest examination in both projections, PA and LAT are more than values recommended by the UK (2000), Brazil and Slovenia. CONCLUSION The present study has determined wide variations in radiation dose of x-ray examinations among hospitals in Mazandaran, Iran. In order to reduce skin dose, an optimization procedure should be considered. Application of a reference dose (DRL) could be a practical method for this purpose. The role of optimization of radiography parameters for reducing patient dose is a significant issue. Through optimizing parameters, it would be possible to preserve image quality while reduction of patient dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran

Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate.  Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

Local reference dose evaluation in conventional radiography examinations in Iran

The goal of this study was to establish local diagnostic reference levels (LDRLs) for conventional radiography examinations in Sistan-Baluchestan province of Iran, using dose area product (DAP) measurements followed by a comparison with international dose levels. DAP factor evaluation was carried out at eight radiography rooms in six public and one private health-care centers. The study employe...

متن کامل

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل