Effects of combining field strengths on auditory functional MRI group analysis: 1.5T and 3T.

نویسندگان

  • Kihwan Han
  • Thomas M Talavage
چکیده

PURPOSE To evaluate effects of combining functional magnetic resonance imaging (fMRI) data acquired from different field strengths on group analysis as a function of the number of subjects at each field strength. MATERIALS AND METHODS In all, 28 subjects (18 at 3T) participated in an auditory task of passively listening to a 0.75s segment of jazz music in an event-related design. Results of single-subject analysis were combined to create all possible subject combinations for a group size of eight subjects from each of the 3T and 1.5T pools, comprising subject mixtures of (3T/1.5T) 0/8, 2/6, 4/4, 6/2, and 8/0. Group analysis performance of each subject permutation was measured by receiver operating characteristic (ROC) curves and activation overlap maps. RESULTS While area under ROC curves, extent of activation in the gold standard region, and reliability of activation increased with the number of 3T subjects, marginal gain decreased. ROC performance overlap across mixtures was observed, indicating that some combinations of subjects markedly outperformed others. For detection of activation, 4/4 was arguably the minimum mixture level that was comparable to 3T-only group results. CONCLUSION Inclusion of 1.5T data does not necessarily reduce the validity of group analysis. Lower field strength data was found only to limit detection power, but did not affect specificity. Within the limits of realignment error, these results should also extend to group longitudinal analyses of subject mixtures from different field strengths.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A robust method to estimate the intracranial volume across MRI field strengths (1.5T and 3T)

As population-based studies may obtain images from scanners with different field strengths, a method to normalize regional brain volumes according to intracranial volume (ICV) independent of field strength is needed. We found systematic differences in ICV estimation, tested in a cohort of healthy subjects (n=5) that had been imaged using 1.5T and 3T scanners, and confirmed in two independent co...

متن کامل

White Matter Hyperintensities on 1.5 and 3 Tesla Brain MRI in Healthy Individuals

Background: White matter hyperintensities (WMH) on T2-weighted magnetic resonance imaging (MRI) are frequent incidental findings in brains of asymptomatic healthy individuals (HI). The morphological and spatial distribution of these WMH between standard 1.5T scanners and increasingly available 3T scanners in a large population of HI in clinical routine settings has not been investigated. Object...

متن کامل

Comparison of MR lymphangiography with a G6 macromolecular contrast agent obtained at 1.5T and 3.0T Systems

Y. Hama, M. Bernardo, Y. Koyama, C. A. Regino, M. W. Brechbiel, P. L. Choyke, H. Kobayashi Molecular Imaging Program, NCI/NIH, Bethesda, Maryland, United States, Molecular Imaging Program, SAIC-Frederick, NCI/NIH, Bethesda, Maryland, United States, Radiation Oncology Branch, NCI/NIH, Bethesda, Maryland, United States Introduction Higher field strength magnets are theoretically superior in signa...

متن کامل

1.5T vs. 3T Body MRI: Qualitative and Quantitative Comparison of T2 Weighted Images for Liver Lesion Detection

J. SZKLARUK, P. R. BHOSALE, A. Balachandran, C. S. NG, E. P. TAMM, J. Ma DIAGNOSTIC RADIOLOGY, MD ANDERSON, HOUSTON, TX, United States Introduction MRI of the liver is routinely used in the staging and follow-up of oncologic patients. The current clinical practice is to use a 1.5T magnet. 3.0T MRI scanners offer superior signal to noise ratio (SNR) over the conventional 1.5T. There are limited ...

متن کامل

Comparison of 1.5T and 3T 1H MR Spectroscopy for Human Brain Tumors

OBJECTIVE We wanted to estimate the practical improvements of 3T proton MR spectroscopy ((1)H MRS) as compared with 1.5T (1)H MRS for the evaluation of human brain tumors. MATERIALS AND METHODS Single voxel (1)H MRS was performed at both 1.5T and 3T in 13 patients suffering with brain tumors. Using the same data acquisition parameters at both field strengths, the (1)H MRS spectra were obtaine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 2011