Creatinine Assay Attainment of Analytical Performance Goals Following Implementation of IDMS Standardization
نویسندگان
چکیده
BACKGROUND The international initiative to standardize creatinine (Cr) assays by tracing reference materials to Isotope Dilution Mass Spectrometry (IDMS) assigned values was implemented to reduce interlaboratory variability and improve assay accuracy. OBJECTIVE The aims of this study were to examine whether IDMS standardization has improved Cr assay accuracy (bias), interlaboratory variability (precision), total error (TE), and attainment of recommended analytical performance goals. METHODS External Quality Assessment (EQA) data (n = 66 challenge vials) from Ontario, Canada, were analyzed. The bias, precision, TE, and the number of EQA challenge vials meeting performance goals were determined by assay manufacturer before (n = 32) and after (n = 34) IDMS implementation. RESULTS The challenge vials with the worst bias and precision were spiked with known common interfering substances (glucose and bilirubin). IDMS standardization improved assay bias (10.4%-1.6%, P < .001), but precision remained unchanged (5.0%-4.7%, P = .5) with performance goals not consistently being met. Precision and TE goals based on biologic variation were attained by only 29% to 69% and 32% to 62% of challenge vials. CONCLUSIONS While IDMS standardization has improved Cr assay accuracy and thus reduced TE, significant interlaboratory variability remains. Contemporary Cr assays do not currently meet the standards required to allow for accurate and consistent estimated glomerular filtration rate assessment and chronic kidney disease diagnosis across laboratories. Further improvements in Cr assay performance are needed.
منابع مشابه
Impact of Isotope Dilution Mass Spectrometry (IDMS) Standardization on Carboplatin Dose and Adverse Events.
BACKGROUND When using area under the concentration-time curve-based strategies for dosing carboplatin, accurate estimation of glomerular filtration rate is required for determining dose. Commonly, the Cockcroft-Gault equation is used, which is dependent on measurement of serum creatinine (SCr). Because analysis of SCr changed to an isotope dilution mass spectrometry (IDMS) standard, we sought t...
متن کاملPaired measurement of urinary creatinine in neonates based on a Jaffe and an enzymatic IDMS-traceable assay
BACKGROUND Urinary creatinine can be quantified by Jaffe or enzymatic assays and is commonly used as denominator of urinary excretion of electrolytes or protein. Paired analysis in pediatric and adult samples documented inter-assay differences (up to 80%). We verified the interchangeability of two IDMS-traceable assays (Jaffe and enzymatic) for neonatal urine and report on neonatal urinary crea...
متن کاملSerum Creatinine: Not So Simple!
Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of se...
متن کاملAnalytical Goals for Point-of-Care Testing Used for Diabetes Management in Australian Health Care Settings Outside The Laboratory
Diabetes mellitus is a major global health problem. Pathology testing for hemoglobin A1c (HbA1c), lipids, and urine albumin/creatinine ratio (ACR) has an important role in the management of diabetes patients. Each of these markers can be performed by point-of-care testing (POCT). This article focuses on setting analytical goals (quality specifications) for the imprecision, bias, and total allow...
متن کاملStandardization and analytical goals for glycated hemoglobin measurement.
Glycated hemoglobin (HbA1c) plays a key role in diagnosing diabetes and monitoring the glycemic state. To guarantee the reliability of its measurement at the global level, the IFCC has defined a reference measurement system, based on the definition of the measurand as hemoglobin molecules having a special hexapeptide in common, which is the stable adduct of glucose to the N-terminal valine of t...