Control Strategy for Discontinuous Conduction Mode Boost Rectifier with Low Total Harmonic Distortion and Improved Dynamic Response

نویسنده

  • H. S. Athab
چکیده

Due to its simplicity, the discontinuous conduction mode boost rectifier is potentially the least expensive active line-harmonics reducing circuit. Problem statement: The line current however, shows considerable distortion when the peak input voltage is close to the output voltage, As a result, the input power factor is poor. This study proposes a simple, low-cost method to reduce the line harmonics. Approach: A periodic voltage signal was injected in the control circuit to vary the duty cycle of the boost switch within a line cycle so that the third-order harmonic of the input current is reduced and the THD is improved. The proposed technique eliminates the additional harmonic generator, phase detecting and phase-locking circuits, which was proposed in the literature. Instead we can utilize the bridge rectifier’s output voltage of the boost converter to modulate the duty cycle of the boost switch. As a result, the injected signal is naturally synchronized with line current. In addition, to obtain nearly constant harmonic content over a wide range of load variation, a modulation index m is used to update the injected signal with a fraction of duty cycle which reflects the load changes. Results: The results proved that third-order harmonic, which was the Lowest Order Harmonic (LOH), can be attenuated by adjusting the modulation index of the injected signal. Moreover, the rectifier shows a good transient performance where the converter’s output voltage overshoots during load and input voltage transients is reduced. Conclusions/Recommendations: The proposed circuit can be used as a front-end converter for DC/DC or DC/AC converters in order to improve the power factor of the input current. Also the proposed control circuit could be integrated in a single chip in order to reduce the cost of the industrial implementation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design for Low Power HB-LED Lighting

This paper presents an improved power quality converter (IPQC) based power supply design for high brightness Light Emitting Diode (HB-LED) low power lighting. The IPQC circuit uses a Cuk buck-boost converter to operate it in discontinuous conduction mode (DCM) using voltage follower technique for the mitigation of harmonic contents present in the AC mains current. Subsequently reduction in harm...

متن کامل

Average Current Control Mode Boost Converter for the Tuningof Total Harmonic Distortion & Power Factor Correction using PSIM

The aim of this paper is to investigate the power factor correction (PFC) of Boost Converter under an average current-mode control. Boost converter topology is used to accomplish this active power-factor correction in many discontinues/ continuous modes. The boost converter is used usually it is easy to implement and works well. In this paper comparative evaluation of different techniques for h...

متن کامل

The Analysis of Ac-dc Boost Pfc Converter Based on Peak and Hysteresis Current Control Techniques

This paper presents two current control techniques of an ac-dc boost converter to obtain unity power factor (PF). Single phase high power factor rectification is the most frequently accomplished using a boost converter. This converter reshapes distorted input current waveform to approximate a sinusoidal current that is in phase with the input voltage. There are several current control technique...

متن کامل

An Improved Integration-reset Controlled Single Phase Unity-power-factor Boost Rectifier with Lower Distortion

This paper proposes an improved integration method to realize single phase power factor correction in continuous conduction mode by adding a ripple compensation network comprised of two resistors to the basic integration control circuitry. This method effectively reduces the total harmonic distortion (THD) in the input current. The proposed method is easy to implement. Theoretical analysis is g...

متن کامل

Simulation of Active Power Factor Correction Using Boost Type Converter

With the vast development in the usage of Power electronic devices like Rectifiers (nonlinear loads) the current drawn from the line is distorted resulting in a High Total Harmonic Distortion (THD) and Low Power Factor (PF). Hence there is a continuous need for Power factor improvement and reduction of line current harmonics. The most popular topology for Active PFC is a boost converter as it d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009