Applanation Tonometry Using One Drop of an Anaesthetic-fluorescein Mixture.

نویسنده

  • P J FENTON
چکیده

THE Goldmann applanation tonometer (1954), as modified by Goldmann and Schmidt (1957), is becoming the standard instrument for measuring the intra-ocular pressure. The accepted method of preparing the eye for a pressure reading is to anaesthetize the cornea and then to stain the pre-corneal film with fluorescein (DukeElder, 1962). The disadvantage of this method is that it requires two manceuvres which are frequently carried out in the dark-room under inadequate illumination. This paper introduces a method of anaesthetizing the cornea and staining the precorneal film with fluorescein using one drop combining the two agents (Fenton, 1964). The problem was twofold. First, to find an anaesthetic which would mix with a fluorescein solution. Secondly, to ensure that the final concentration of the two constituents was adequate for their respective functions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applanation Tonometry Using Anaesthetic-fluorescein Mixture.

SIRs,-In your April issue (Brit. J. Ophthal., 1965, 49, 205) you published my paper "Applanation Tonometry using One Drop of an Anaesthetic-Fluorescein Mixture". This paper recommended a mixture containing 0 3 per cent. Novesine and 0)125 per cent. fluorescein; one drop gave good corneal anaesthesia and a good fluorescent ring for Goldmann applanation tonometry. Of the eight anaesthetic solutio...

متن کامل

A comparative study of proxymetacaine-fluorescein and lignocaine-fluorescein use during applanation tonometry.

AIMS To evaluate the relative merits of proxymetacaine-fluorescein (PROX-FLU) and lignocaine-fluorescein (LIG-FLU) when used to perform applanation tonometry. METHODS This prospective, masked, double blind study assessed several aspects of the tonometry process-the duration of the stinging sensation and degree of discomfort, the extent of reflex lacrimation induced, the need for subsequent te...

متن کامل

Goldmann Applanation Tonometry: Using a Red-Free Filter for Mass Screening

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. Goldmann applanation tonometry is the gold standard medical instrument for the ...

متن کامل

Goldmann tonometry tear film error and partial correction with a shaped applanation surface

Purpose The aim of the study was to quantify the isolated tear film adhesion error in a Goldmann applanation tonometer (GAT) prism and in a correcting applanation tonometry surface (CATS) prism. Methods The separation force of a tonometer prism adhered by a tear film to a simulated cornea was measured to quantify an isolated tear film adhesion force. Acrylic hemispheres (7.8 mm radius) used a...

متن کامل

Rapid pneumatic and Mackay-Marg applanation tonometry

Glaucoma is usually considered to be adequately controlled when Goldmann applanation readings are below 22 mmHg. It is, however, now known that the intraocular pressure increases to a varying degree when the patient changes his posture from sitting to a recumbent position (Galin, McIvor, and Magruder, I963; Roberts and Rogers, I964; Hetland-Eriksen, Ig66a; Inglima, I966; Tarkkanen and Leikola, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 49  شماره 

صفحات  -

تاریخ انتشار 1965