Design and simulation of a GEM-based TEPC as a neutron REM meter.

نویسندگان

  • C K Wang
  • M Seidaliev
  • A K Mandapaka
چکیده

A new plate-like tissue equivalent proportional counter (TEPC) based on the gas electron multiplier (GEM) is being developed for use as a neutron rem meter. The advantage of a plate-like TEPC over a conventional spherical TEPC is that several of the plate-like TEPCs can be stacked together as one unit to increase sensitivity to neutrons. A GEM-based TEPC consists of four layers of materials in a series: the front cover made of polyethylene, the cathode made of A-150 plastic, the gas region containing 1/3 atm of P-10 and 1/3 atm of nitrogen and the anode made of a copper-coated printed circuit board. The dimensions of the TEPC are 10 cm x 10 cm x 1.8 cm. The computer simulation shows that the neutron response function of the TEPC closely resembles the response curve of H(10) for neutrons with energies between 0.25 eV and 10 MeV. The corresponding sensitivity for such a TEPC for a bare (252)Cf neutron source was calculated to be 5.0 cpm per microSv h(-1). This sensitivity can be increased many times by simply stacking several TEPCs together as one unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and test of a GEM-based TEPC for neutron protection dosimetry.

A novel tissue-equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10) for neutrons was designed and constructed. The pulse height spectra (PHS) of two different neutron sources (a 252Cf source and a AmBe source) were measured using the new TEPC. The measurements were made with the TEPC filled with two different gases (10P gas and a propane-based tis...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Microdosimetric Measurements with a GEM-TEPC with 62 AMeV Carbon Ions

The microdosimetric characterization represents a useful method for the quality assessment of hadron beams [1,2]. These distributions can be measured by means of Tissue Equivalent Proportional Counters (TEPCs) [3]. Besides, the possibility of performing dosimetry and quality assessment at the same time allows a detailed picture of the physical properties of clinical beams and permits the invest...

متن کامل

An accurate and portable solid state neutron rem meter

Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may...

متن کامل

A performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation

  PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets.   experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the  ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 126 1-4  شماره 

صفحات  -

تاریخ انتشار 2007