Size of the foveal blue scotoma related to the shape of the foveal pit but not to macular pigment
نویسندگان
چکیده
When the eye is covered with a filter that transmits light below 480 nm and a blue field is observed on a computer screen that is modulated in brightness at about 1 Hz, the fovea is perceived as small irregular dark spot. It was proposed that the "foveal blue scotoma" results from the lack of S-cones in the foveal center. The foveal blue scotoma is highly variable among subjects. Possible factors responsible for the variability include differences in S-cone distribution, in foveal shape, and in macular pigment distribution. Nine young adult subjects were instructed to draw their foveal blue scotomas on a clear foil that was attached in front of the computer screen. The geometry of their foveal pit was measured in OCT images in two dimensions. Macular pigment distribution was measured in fundus camera images. Finally, blue scotomas were compared with Maxwell's spot which was visualized with a dichroic filter and is commonly assumed to reflect the macular pigment distribution. The diameters of the foveal blue scotomas varied from 15.8 to 76.4 arcmin in the right eyes and 15.5 to 84.7 arcmin in the left and were highly correlated in both eyes. It was found that the steeper the foveal slopes and the narrower the foveal pit, the larger the foveal blue scotoma. There was no correlation between foveal blue scotoma and macular pigment distribution or Maxwell's spot. The results are therefore in line with the assumption that the foveal blue scotoma is a consequence of the lack of S-cones in the foveal center. Unlike the foveal blue scotoma, Maxwell's spot is based on macular pigment as previously proposed.
منابع مشابه
Unveiling the foveal blue scotoma through an afterimage
The absence of short-wave-sensitive (S-) cones in the human foveola normally goes unnoticed, but the resulting foveal S-cone, or blue, scotoma can be visualized as the negative afterimage of a short-wavelength adapting field on a larger white background. The afterimage has an annular shape with a lighter inner region that corresponds to Maxwell's spot, and a small bright spot in the center corr...
متن کاملEvaluation of the Vascular Density, the Area of Foveal Avascular Zone, and Corrected Vision in Patients with Diabetic Macular Edema after Anti-VEGF Therapy
Background and Objective: This study aimed to evaluate the changes in macular superficial and deep capillary plexus (SCP and DCP) density, Foveal Avascular Zone (FAZ) area, and visual acuity in patients with diabetic macular edema after anti-VEGF therapy. Materials and Methods: This descriptive-analytical study utilized before and after treatment design. In total, 30 eyes of 30 patients with d...
متن کاملScanning laser ophthalmoscope correlations with biomicroscopic findings and foveal function after macular hole closure.
OBJECTIVE To investigate the relation between foveal findings and visual function in eyes with a resolved idiopathic macular hole after vitreous surgery. METHODS We divided 28 eyes with postoperative idiopathic macular hole resolution into 3 groups based on postoperative biomicroscopic foveal findings of complete closure, partial closure, or atrophic closure. To evaluate foveal retinal functi...
متن کاملFoveal cone photopigment distribution: small alterations associated with macular pigment distribution.
PURPOSE To map the photopigment distribution of central foveal cones in healthy adult subjects before potential onset of age-related macular degeneration. To compare alterations in cone photopigment distribution to those of macular pigment and examine those loci for subretinal changes. METHODS Eleven healthy subjects (age range, 31-59 years) underwent reflectometry with a scanning laser ophth...
متن کاملThe relationship between foveal short-wavelength-sensitive visual function and macular pigment optical density in the ageing age
To investigate the role of macular pigment in preserving foveal short-wavelength-sensitive (SWS) visual function in the ageing eye orientation identification acuity was measured in the fovea and at 12° eccentricity (nasal visual field) under SWS-cone isolating conditions in 73 participants (aged 20-71). Macular pigment optical density (MPOD) was measured at 0.5° eccentricity from the foveal cen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 106 شماره
صفحات -
تاریخ انتشار 2015