Accurate dispensing of volatile reagents on demand for chemical reactions in EWOD chips.
نویسندگان
چکیده
Digital microfluidic chips provide a new platform for manipulating chemicals for multi-step chemical synthesis or assays at the microscale. The organic solvents and reagents needed for these applications are often volatile, sensitive to contamination, and wetting, i.e. have contact angles of <90° even on the highly hydrophobic surfaces (e.g., Teflon® or Cytop®) typically used on digital microfluidic chips. Furthermore, often the applications dictate that the processes are performed in a gas environment, not allowing the use of a filler liquid (e.g., oil). These properties pose challenges for delivering controlled volumes of liquid to the chip. An automated, simple, accurate and reliable method of delivering reagents from sealed, off-chip reservoirs is presented here. This platform overcomes the issues of evaporative losses of volatile solvents, cross-contamination, and flooding of the chip by combining a syringe pump, a simple on-chip liquid detector and a robust interface design. The impedance-based liquid detection requires only minimal added hardware to provide a feedback signal to ensure accurate volumes of volatile solvents are introduced to the chip, independent of time delays between dispensing operations. On-demand dispensing of multiple droplets of acetonitrile, a frequently used but difficult to handle solvent due to its wetting properties and volatility, was demonstrated and used to synthesize the positron emission tomography (PET) probe [(18)F]FDG reliably.
منابع مشابه
Modification of an automated liquid-handling system for reagent-jet, nanoliter-level dispensing.
Reducing the scale of biochemical reactions is becoming commonplace. Examples include the screening of large libraries of chemical compounds or gene sequences. These applications demand the ability to transfer sub-microliter volumes of fluid. To this end, we have modified a Hamilton MICROLAB 2200 with high-speed solenoids and a liquid pressurization system to modulate volume delivery down to th...
متن کاملValidated UV-Vis Spectrophotometric Method for Determination of Gabapentin using Acetyl Acetone and Formaldehyde Reagents
Gabapentin is an anticonvulsant widely used in the treatment of epilepsy.An accurate and validated spectrophotometric method was developed as an alternative method to determine gabapentin in pharmaceutical products. This is a simple, accurate, precise, selective and visible spectrophotometric method. The method is based on the measurement of drug absorbance as a result of yellow solution format...
متن کاملRecent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...
متن کاملProduction of Fish Chips from Sand Smelt (Atherina boyeri, RISSO 1810) and Determination of Some Quality Changes
In this study, changes in some quality parameters of fish chips produced from sand smelt (Atherina boyeri, RISSO 1810) during storage period (at -18 o C for 6 months) were determined. The difference between the amount of moisture, crude protein, crude fat and crude ash components of raw fish in fish chips was significant (P<0.05). Pre-frying process resulted in a decrease in all fatty acid c...
متن کاملProduction of Fish Chips from Sand Smelt (Atherina boyeri, RISSO 1810) and Determination of Some Quality Changes
In this study, changes in some quality parameters of fish chips produced from sand smelt (Atherina boyeri, RISSO 1810) during storage period (at -18 o C for 6 months) were determined. The difference between the amount of moisture, crude protein, crude fat and crude ash components of raw fish in fish chips was significant (P < 0.05). Pre-frying process resulted in a decrease in all fatty acid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 12 18 شماره
صفحات -
تاریخ انتشار 2012