Assessing total body and extracellular water from bioelectrical response spectroscopy.

نویسندگان

  • S F Siconolfi
  • R J Gretebeck
  • W W Wong
  • R A Pietrzyk
  • S S Suire
چکیده

We developed and validated assessments for total body water (TBW) and extracellular water (ECW) by using two resistance values of a new electric circuit model (CM) (two resistors; a capacitor and an inductor) with or without body mass. Fluid shifts occurring after 40 min of supine rest did not increase the validity of either estimate. CM estimates were valid; r = 0.941 to 0.969, low SE of estimates of 1.15-2.28 kg, nonsignificant mean differences (CM - dilution; %delta = -0.4 to 1.3%) that were close to the expected measurement errors for TBW (+/- 1%) and ECW (+/- 5%), and Bland-Altman pairwise comparisons that showed equivalence between methods. The CM estimates of TBW and ECW had marginally better validity than the previously published bioimpedance models. The advantage of the CM model is its assessments of multiple fluid spaces and that it does not require gender-specific equations. We conclude that CM estimate of TBW is acceptable, whereas further validation is needed before the ECW estimate should be used in a clinical or research setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Body Water Distribution and Risk of Cardiovascular Morbidity and Mortality in a Healthy Population: A Prospective Cohort Study

BACKGROUND Early alterations in the cardiovascular structure and function may change normal body water distribution. The resulting fluid shifts may thus serve as an early marker for cardiovascular disease. However, studies examining this in healthy populations are absent. OBJECTIVE This study examined the association between the proportion of total body water that is extracellular water and s...

متن کامل

Estimation of body water compartments in cirrhosis by multiple-frequency bioelectrical-impedance analysis.

Estimation of total body water by measuring bioelectrical impedance at a fixed frequency of 50 kHz is useful in assessing body composition in healthy populations. However, in cirrhosis, the distribution of total body water between the extracellular and intracellular compartments is of greater clinical importance. We report an evaluation of a new multiple-frequency bioelectrical-impedance analys...

متن کامل

Bioelectrical impedance spectroscopy for the assessment of body fluid volumes of term neonates.

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop...

متن کامل

Human hydrometry: comparison of multifrequency bioelectrical impedance with H2O and bromine dilution

Ellis, Kenneth J., and William W. Wong. Human hydrometry: comparison of multifrequency bioelectrical impedance with H2O and bromine dilution. J. Appl. Physiol. 85(3): 1056–1062, 1998.—The traditional method of assessing total body water (TBW), extracellular water (ECW), and intracellular water (ICW) has been the use of isotopes, on the basis of the dilution principle. Although the development o...

متن کامل

Measurement of nutritional status in simulated microgravity by bioelectrical impedance spectroscopy.

The potential of bioelectrical impedance spectroscopy (BIS) for assessing nutritional status in spaceflight was tested in two head-down-tilt bed-rest studies. BIS-predicted extracellular water (ECW), intracellular water (ICW), and total body water (TBW) measured using knee-elbow electrode placement were compared with deuterium and bromide dilution (DIL) volumes in healthy, 19- to 45-yr-old subj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 1997