Intensity modulated proton therapy.

نویسندگان

  • H M Kooy
  • C Grassberger
چکیده

Intensity modulated proton therapy (IMPT) implies the electromagnetic spatial control of well-circumscribed "pencil beams" of protons of variable energy and intensity. Proton pencil beams take advantage of the charged-particle Bragg peak-the characteristic peak of dose at the end of range-combined with the modulation of pencil beam variables to create target-local modulations in dose that achieves the dose objectives. IMPT improves on X-ray intensity modulated beams (intensity modulated radiotherapy or volumetric modulated arc therapy) with dose modulation along the beam axis as well as lateral, in-field, dose modulation. The clinical practice of IMPT further improves the healthy tissue vs target dose differential in comparison with X-rays and thus allows increased target dose with dose reduction elsewhere. In addition, heavy-charged-particle beams allow for the modulation of biological effects, which is of active interest in combination with dose "painting" within a target. The clinical utilization of IMPT is actively pursued but technical, physical and clinical questions remain. Technical questions pertain to control processes for manipulating pencil beams from the creation of the proton beam to delivery within the patient within the accuracy requirement. Physical questions pertain to the interplay between the proton penetration and variations between planned and actual patient anatomical representation and the intrinsic uncertainty in tissue stopping powers (the measure of energy loss per unit distance). Clinical questions remain concerning the impact and management of the technical and physical questions within the context of the daily treatment delivery, the clinical benefit of IMPT and the biological response differential compared with X-rays against which clinical benefit will be judged. It is expected that IMPT will replace other modes of proton field delivery. Proton radiotherapy, since its first practice 50 years ago, always required the highest level of accuracy and pioneered volumetric treatment planning and imaging at a level of quality now standard in X-ray therapy. IMPT requires not only the highest precision tools but also the highest level of system integration of the services required to deliver high-precision radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in Intensity Modulated Proton Therapy Treatment Planning Optimization

Radiation therapy is a non-invasive treatment modality for cancer patients. Radiation therapy treatment planning for cancer patients provides many challenging optimization problems. Various variables of a treatment plan need to be optimized so that the resulting plan can kill all cancerous cells while minimizing damage on the patient’s normal tissues. Intensity modulated proton therapy (IMPT) h...

متن کامل

Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy

PURPOSE The aim of the present study was to compare the dose distribution generated from photon volumetric modulated arc therapy (VMAT), intensity modulated proton therapy (IMPT), and intensity modulated carbon ion therapy (IMCIT) in the delivery of hypo-fractionated thoracic radiotherapy. METHODS AND MATERIALS Ten selected patients who underwent thoracic particle therapy between 2015 and 201...

متن کامل

Intensity-modulated proton therapy for nasopharyngeal carcinoma: Decreased radiation dose to normal structures and encouraging clinical outcomes.

BACKGROUND Intensity-modulated proton therapy (IMPT) has the potential to spare dose to organs at risk (OAR) when compared to intensity-modulated radiotherapy (IMRT) while maintaining excellent clinical outcomes. METHODS Ten patients with nasopharyngeal carcinoma (NPC) were identified for whom IMPT was planned; 9 patients also had a comparison photon-based IMRT plan generated. Dosimetric comp...

متن کامل

Intensity Modulated Proton Therapy as a Boost Treatment after Prostate Seed Implant: A Treatment Planning Study

Purpose: Combination of Prostate Seed Implant (PSI) with External Beam Radiation Therapy (EBRT) remains as an attractive option for patients with intermediate or high-risk prostate cancer. One of the most widely used approaches is to use external beam radiation therapy (EBRT) to deliver boost doses after permanent prostate seed implant (PSI). In this study, the feasibility of using Intensity Mo...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 88 1051  شماره 

صفحات  -

تاریخ انتشار 2015