Mechanism of interference by hemoglobin in the determination of total bilirubin. II. Method of Jendrassik-Grof.

نویسندگان

  • B C Shull
  • H Lees
  • P K Li
چکیده

Oxyhemoglobin in erythrocyte hemolysates interferes with the Jendrassik-Grof assay. Destruction of azobilirubin occurs when oxyhemoglobin is oxidized to methemoglobin during diazotization or to alkaline hematin with addition of alkaline tartrate. The most probable mechanism is by oxidation with an agent such as hydrogen peroxide or a related species resulting from hemoglobin oxidation. Methemoglobin also appears to cause some destruction of azobilirubin during diazotization. Methemoglobin forms during diazotization because of reactions of oxyhemoglobin with both diazo reagent and nitrite ion. Formation of methemoglobin is, therefore, more rapid in the test than in the blank mixture and, under reaction conditions, its absorbance is less than that of oxyhemoglobin. This results in spectral interference when neutral azobilirubin is assayed. Alkaline tartrate abolishes this spectral error by causing rapid formation of alkaline hematin in both test and blank.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.

We automated the Jendrassik-Grof method for measurement of bilirubin with the Greiner Selective Analyzer GSA II D. Comparison with the manual Jendrassik-Grof method showed a highly significant correlation coefficient of 0.994 for total and 0.980 for "direct" bilirubin measurement. The automated method showed good precision and was linear to 667 mu mol/L, the highest concentration tested. Additi...

متن کامل

Studies on the interference by haemoglobin in the determination of bilirubin.

Haemoglobin interference in the determination of bilirubin was compared in 7 different methods using the Jendrassik-Grof procedure, the Jendrassik-Grof-Nosslin modification, and the more recent procedures using nitrophenyldiazonium, 2,5-dichlorophenyldiazonium, 2,4-dichloraniline, and a direct reading method. To a variable degree, haemoglobin decreased the apparent absorption of the reaction pr...

متن کامل

Modified Jendrassik--Grof method for bilirubins adapted to the Abbott Bichromatic Analyzer.

I describe a semi-micro method for use with a discrete analyzer, the Abbott ABA-100, requiring 75 microliter of sample for determination of both the total and direct bilirubins. This method utilizes a serum blank. It is simple and reasonably rapid. The azobilirubin formed by both the total and the direct bilirubins produces a reddish-violet color, which is measured at 550 nm. Values obtained ar...

متن کامل

Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.

We describe two centrifugal analyzer methods for measuring total bilirubin in serum. Diazotized 2-chloroaniline-5-sulfonic acid is used in both. In the first procedure, ethylene glycol and methanol are used as an accelerator solvent; results correlate well with those by a Jendrassik and Grof method adapted to the centrifugal analyzer, but there is considerable hemolysis interference. In the sec...

متن کامل

Improved method for accurate quantitation of total and conjugated bilirubin in serum.

We describe an improved method for the quantitation of total and direct bilirubin in serum in which sodium dodecyl sulfate is used as an accelerator. Viscous and caustic reagents are not needed, and the effects of protein matrix, hemoglobin interference, and turbidity are minimized. For total bilirubin determination we first add the sodium dodecyl sulfate reagent to serum, then a diazo reagent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 1980