Effect of Reconstruction Filter on Image in Dental Cone Beam Computed Tomography

نویسندگان

  • Yoshie Kodera
  • Yuuki Houno
  • Dae Hong Kim
  • Hee Joung Kim
  • Takanori Ishii
  • Yuki Saito
  • Haruo Isoda
  • K. Goto
  • Y. Kodera
چکیده

1. Effect of reconstruction filter on image in dental cone beam computed tomography Yuuki Houno 2. Characteristics of image in dual-energy computed tomography(CT) imaging Dae Hong Kim 3. Verification of lateral biological dose distribution with microdosimetric kinetic model in carbon-ion radiotherapy Mikoto Tamura 4. The imparct of secondary particles on in-beam PET imaging for dose verification in carbon ion therapy 5. Evaluation of radiation dose to organs and tissues in infant X-ray CT Takanori Ishii 6. Digital breast tomosynthesis and digital mammography-A comparison of figures of merit for various average glandular doses Ye Sle Kim 7. Reduction of patient dose in digital mammography: Simulation of low-dose image from routine-dose Yuki Saito-15 minutes rest – Introduction Recently, dentistry diagnoses have been performed using panoramic radiography or dental X-rays, but cone-beam CT (CBCT), which can obtain more information, has been gaining attention. CBCT has high spatial resolution, but it is difficult to describe that teeth and alveolar bones separately because the reconstructed image is blurred. It is important to know the condition of alveolar bones in diagnosis of periodontal disease or simulation of implant placement. In CBCT, spatial resolution is influenced by machine characteristics such as detector spacing, focal spot size, and overall geometry. In addition, reconstruction parameters such as the voxel size and reconstruction filter influence the spatial resolution. However, users cannot change the machine characteristics. Thus, we examined the use of a reconstruction filter to provide a sharp image.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study

Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012