PRFS-Based MR Thermometry Versus an Alternative T1 Magnitude Method – Comparative Performance Predicting Thermally Induced Necrosis in Hepatic Tumor Ablation

نویسندگان

  • Christian Rosenberg
  • Antje Kickhefel
  • Birger Mensel
  • Tilman Pickartz
  • Ralf Puls
  • Joerg Roland
  • Norbert Hosten
چکیده

OBJECTIVE To compare the accuracy of a semi-quantitative proton resonance frequency shift (PRFS) thermal mapping interface and an alternative qualitative T1 thermometry model in predicting tissue necrosis in an established routine setting of MRI-guided laser ablation in the human liver. MATERIALS AND METHODS 34 cases of PRFS-guided (GRE) laser ablation were retrospectively matched with 34 cases from an earlier patient population of 73 individuals being monitored through T1 magnitude image evaluation (FLASH 2D). The model-specific real-time estimation of necrotizing thermal impact (above 54 °C zone and T1 signal loss, respectively) was correlated in size with the resulting necrosis as shown by lack of enhancement on the first-day contrast exam (T1). Matched groups were compared using the Mann-Whitney test. RESULTS Online PRFS guidance was available in 33 of 34 cases. Positive size correlation between calculated impact zone and contrast defect at first day was evident in both groups (p < 0.0004). The predictive error estimating necrosis was median 21% (range 1 %-52%) in the PRFS group and 61 % (range 22-84%) in the T1 magnitude group. Differences in estimating lethal impact were significant (p = 0.004), whereas the real extent of therapy-induced necrosis showed no significant difference (p > 0.28) between the two groups. CONCLUSION PRFS thermometry is feasible in a clinical setting of thermal hepatic tumor ablation. As an interference-free MR-tool for online therapy monitoring its accuracy to predict tissue necrosis is superior to a competing model of thermally induced alteration of the T1 magnitude signal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo

BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR t...

متن کامل

Results from clinical phase I study on breast tumor ablation with dedicated breast MR-HIFU system

Methods All treatments were performed on a dedicated breast MR-HIFU system (Philips Healthcare, Vantaa, Finland) integrated with a clinical 1.5-T MRI scanner (Achieva, Philips Healthcare, Best, The Netherlands). Ten female patients with i) pathologically proven invasive breast cancer after large-core needle biopsy and ii) tumor size ≥ 1 cm were included. The patients were under procedural sedat...

متن کامل

The magnetic susceptibility effect of gadolinium-based contrast agents on PRFS-based MR thermometry during thermal interventions

BACKGROUND Proton resonance frequency shift (PRFS) magnetic resonance (MR) thermometry exploits the local magnetic field changes induced by the temperature dependence of the electron screening constant of water protons. Any other local magnetic field changes will therefore translate into incorrect temperature readings and need to be considered accordingly. Here, we investigated the susceptibili...

متن کامل

MR temperature imaging using PRF phase difference and a geometric model-based fat suppression method.

BACKGROUND Because protons in fat do not exhibit a temperature-dependent frequency shift, proton resonance frequency shift (PRFS)-based MR thermometry always suffers from disturbances due to the presence of fats or lipids. OBJECTIVE A new fat suppression method for PRFS-based MR thermometry is proposed to obtain accurate variation of phase angle. METHODS Similar to the approach of separatin...

متن کامل

MRgRFA: physical model and first order correction of PRFS thermometry corrupted by magnetic susceptibility-mediated cavitation’s effects

Introduction MR thermometry based on the proton resonance frequency (PRF) method (1) has gained good acceptance for guiding RF ablation of liver tumors (2). Major artifacts in the PRFS thermometry have recently been reported related to per-operatory changes of the tissue bulk susceptibility during RF heating (3). They are originating from gas bubbles formation, known as white cavitations’ artif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013