Parameter estimation from magnitude MR images
نویسندگان
چکیده
This article deals with the estimation of model-based parameters, such as the noise variance and signal components, from magnitude magnetic resonance (MR) images. Special attention has been paid to the estimation of T1and T2-relaxation parameters. It is shown that most of the conventional estimation methods, when applied to magnitude MR images, yield biased results. Also, it is shown how the knowledge of the proper probability density function of magnitude MR data (i.e., the Rice distribution) can be exploited so as to avoid (or at least reduce) such systematic errors. The proposed method is based on maximum likelihood (ML) estimation. © 1999 John Wiley & Sons, Inc. Int J Imaging Syst Technol, 10, 109–114, 1999
منابع مشابه
On the Expectation-Maximization algorithm for Rice-Rayleigh mixtures with application to noise parameter estimation in magnitude MR datasets
Magnitude magnetic resonance (MR) images are noise-contaminated measurements of the true signal, and it is important to assess the noise in many applications. A recently introduced approach models the magnitude MR datum at each voxel in terms of a mixture of upto one Rayleigh and an a priori unspecified number of Rice components, all with a common noise parameter. The Expectation-Maximization (...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملSingle station estimation of earthquake early warning parameters by using amplitude envelope curve
In this study, new empirical relationships to estimate key parameters in Earthquake Early Warning (EEW) system including magnitude, epicentral distance and Peak Ground Acceleration (PGA) are introduced based on features of the initial portion of P-wave’s amplitude envelope curve. For this purpose, 226 time series recorded by bore-hole accelerometers of Japanese KiK-net are processed for earthq...
متن کاملA Comparative Analysis of Noise Reduction Filters in MRI Images
------------------------------------------------------------------------------------------------------------------------------------------------------------Abstract Post inheritance denoising of magnetic resonance (MR) images is of emphatic for clinical diagnosis and computerized decisive test, such as tissue classification and segmentation. It has been exposed that when signal to noise ratio (...
متن کاملThe Effect of Motion Correction on Pharmacokinetic Parameter Estimation
A dynamic-contrast-enhanced magnetic resonance imaging (DCE-MRI) dataset consists of many imaging frames, often acquired both before and after contrast injection. Due to the length of time spent acquiring images, patient motion is likely and image re-alignment or registration is required before further analysis such as pharmacokinetic model fitting. Non-rigid image registration procedures may b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Int. J. Imaging Systems and Technology
دوره 10 شماره
صفحات -
تاریخ انتشار 1999