Should the galvanic combination of titanium and stainless steel surgical implants be avoided?

نویسندگان

  • Paul Johan Høl
  • Anders Mølster
  • Nils Roar Gjerdet
چکیده

It is recommended that one should not combine different metals in orthopaedic devices. The least noble metal in such a galvanic coupling is more likely to corrode. However, some studies have failed to show increased corrosion when titanium and stainless steel are combined. The aim of this study was to determine the fretting corrosion of the contact areas between screws and plates made of these dissimilar metals used for internal fixation of bone fractures. The plates were fixed to a bone-simulating material and subjected to tensile and compressive forces in both human serum and Hank's solution. The outcome variables included in the analyses were weight loss, and release of Ti, Cr, Ni and Mo to the different media. Results from the multiple combinations were subjected to multivariate statistics. Principal component analysis visualised our findings and allowed classification of similar samples and separation of discrepant groups of samples. We found a significant effect of the test medium, but no dramatic effect due to mixing of metals. The titanium screws and plates corroded more in serum than in saline, while the opposite was true for stainless steel. Combination of dissimilar screws and plates did not cause higher weight loss or metal release than the single-material constructions, indicating comparable clinical safety.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mixing implants of differing metallic composition in the treatment of upper-extremity fractures.

Mixing implants with differing metallic compositions has been avoided for fear of galvanic corrosion and subsequent failure of the implants and of bone healing. The purpose of this study was to evaluate upper-extremity fractures treated with open reduction and internal fixation with metallic implants that differed in metallic composition placed on the same bone. The authors studied the effects ...

متن کامل

Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?

BACKGROUND CONTEXT Surgeons are hesitant to mix components made of differing metal classes for fear of galvanic corrosion complications. However, in vitro studies have failed to show a significant potential for galvanic corrosion between titanium and stainless steel, the two primary metallic alloys used for spinal implants. Galvanic corrosion resulting from metal mixing has not been described i...

متن کامل

Comparison of galvanic corrosion potential of metal injection molded brackets to that of conventional metal brackets with nickel-titanium and copper nickel-titanium archwire combinations.

AIM The aim of the study is to investigate the galvanic corrosion potential of metal injection molding (MIM) brackets to that of conventional brackets under similar in vitro conditions with nickel-titanium and copper nickel-titanium archwires. MATERIALS AND METHODS Twenty-five maxillary premolar MIM stainless steel brackets and 25 conventional stainless steel brackets and archwires, 0.16 inch...

متن کامل

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group ...

متن کامل

Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study

BACKGROUND Technological advances in wire selection and bracket design have led to improved treatment efficiency and allowed longer time intervals between appliance adjustments. The wires remain in the mouth for a longer duration and are subjected to electrochemical reactions, mechanical forces of mastication and generalized wear. These cause different types of corrosion. This study was done to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Injury

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2008