Spring-loaded Syringe for Multiple Rapid Injections

نویسندگان

  • CR Srinivas
  • Anirudh Somani
  • CK Shashidharan Nair
  • Thirumurthy Mylswamy
چکیده

Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of spring-loaded, loss of resistance and hanging drop techniques in lumbar epidural blocks.

OBJECTIVES The spring-loaded syringe is a loss of resistance syringe that provide a more objective sign that the epidural space has been entered compared with the traditional techniques. The aim of this study was to compare the time required to locate the epidural space and the backache incidence with the spring-loaded (SL), loss of resistance (LOR) and the hanging drop (HD) techniques for epid...

متن کامل

بررسی نتایج استفاده مجدد از سرنگهای یک بار مصرف انسولین در بیماران وابسته به انسولین مراجعه کننده به درمانگاه شهید مطهری شیراز

Background: In spite of a high risk of infection, multiple usages of disposable insulin syringes among diabetic patients is quite common. The present study was designed to assess the outcome of multiple usages of disposable insulin syringes in insulin dependent patients referring to Shahid Motahari clinic in Shiraz . Materials and methods: For this descriptive study, through a random sampling m...

متن کامل

Pharmacokinetics and glucodynamics of rapid-, short-, and intermediate-acting insulins: comparison of jet injection to needle syringe.

863 Dear Editor: Insulin-requiring diabetes, whether resulting from type 1 or from progression of type 2 disease, requires strict attention to glycemic control in order to reduce the incidence of microand macrovascular complications. To approach the goal of euglycemia, individualized patient treatment may demand an intensive regimen, which can negatively impact patient compliance due to the “fe...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Rapid assessment of injection practices in Cambodia, 2002

BACKGROUND Injection overuse and unsafe injection practices facilitate transmission of bloodborne pathogens such as hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Anecdotal reports of unsafe and unnecessary therapeutic injections and the high prevalence of HBV (8.0%), HCV (6.5%), and HIV (2.6%) infection in Cambodia have raised concern over injection s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017