Hypersensitivity in aseptic loosening of total hip replacements. The role of constituents of bone cement.

نویسندگان

  • F S Haddad
  • A G Cobb
  • G Bentley
  • N J Levell
  • P M Dowd
چکیده

Aseptic loosening is seen in a significant proportion of cemented total hip replacements (THR). In a small subgroup of patients who suffer early loosening polyethylene debris is unlikely to be responsible. We recently reported one case of allergic contact dermatitis to N,N-dimethylparatoluidine (DMT), an accelerator used in bone cement. We have therefore investigated this using skin-patch tests to a variety of substances including metals, polyethylene and the separated individual components of Simplex cement. We studied 70 patients, 15 with aseptic loosening less than two years after THR, 25 with satisfactory long-term cemented fixation, five with infected loosening of cemented THRs and 25 awaiting hip arthroplasty. We found seven positive reactions to DMT, all of them in patients with the rapid onset of aseptic loosening. Allergy to DMT is recognized in the dental profession in respect of the 'denture sore mouth' syndrome, and could also be an occupational hazard since some industrial glues contain DMT. Our results suggest the need for awareness of possible previous dental or occupational exposure of the constituents of bone cement. We recommend the use of skin-patch testing in high-risk cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Cement Mantle in Relation to Surgical Approach

Aseptic loosening remains the commonest cause of failure of total hip arthroplasty. Cement mantle defects are associated with aseptic loosening. Cementing technique has a profound influence on the incidence of aseptic loosening of total hip replacements. Two specific measures that seem to have the greatest impact on the longevity of cemented femoral stems are pressurization of cement and contro...

متن کامل

0536 - the Effect of Radio-opacifiers in Bone Cement on an in Vivo Model of Aseptic Loosening

INTRODUCTION Aseptic loosening is the commonest cause of failure of total joint replacements. The pathogenesis of this process remains controversial but appears to involve prosthetic migration, joint fluid pressure and the host response to particulate wear debris. The Swedish Hip Registry has shown that the type of bone cement used effects the risk of revision for aseptic loosening. It has been...

متن کامل

Loosening of the femoral component after total hip replacement. The thin black line and the sinking hip.

Review of the radiographs of 882 consecutive metal-to-polyethylene hip replacements after a mean follow-up of 6.8 years showed 72 cases (8%) of aseptic femoral loosening, all of which showed a lucent zone or black line between metal and cement. In 97% of the series this appeared within two years of the arthroplasty. Progress of loosening was unpredictable and only 24% had significant symptoms. ...

متن کامل

Radiological features predictive of aseptic loosening in cemented Charnley femoral stems.

The radiological features of the cement mantle around total hip replacements (THRs) have been used to assess aseptic loosening. In this case-control study we investigated the risk of failure of THR as predictable by a range of such features using data from patients recruited to the Trent Regional Arthroplasty Study (TRAS). An independent radiological assessment was undertaken on Charnley THRs w...

متن کامل

The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review.

Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 78 4  شماره 

صفحات  -

تاریخ انتشار 1996