A primary method for determination of optical parameters of turbid samples and application to intralipid between 550 and 1630 nm.
نویسندگان
چکیده
The lack of a primary method for determination of optical parameters remains a significant barrier in optical study of turbid media. We present a complete system of experimental setups and Monte Carlo modeling tools for fast and accurate solution of the inverse problem from the measured signals of homogeneous turbid samples. The calibration of the instrument and validation of the Monte Carlo modeling have been carried out to ensure the accuracy of the inverse solution. We applied this method to determine the optical parameters of turbid media of 10% intralipid between 550 and 940 nm and 20% intralipid between 550 and 1630 nm.
منابع مشابه
Determination of refractive indices of porcine skin tissues and intralipid at eight wavelengths between 325 and 1557 nm.
We constructed an automated reflectometry system for accurate measurement of coherent reflectance curves of turbid samples and analyzed the presence of coherent and diffuse reflection near the specular reflection angle. An existing method has been validated to determine the complex refractive indices of turbid samples on the basis of nonlinear regression of the coherent reflectance curves by Fr...
متن کاملDesign and Evaluation of a Novel Bismuth Optical Sensor Using PC-ANN Application
The characterization of and construction of a new optical sensor based on the immobilization of Pyrocatechol Violet on a triacetylcellulose membrane was described to for the determination of bismuth (III) in real samples. The interaction between sensing membrane and bismuth (III) was caused at pH 3.80 in acetate buffer solution and the color changed from yellow to blue along with the appearance...
متن کاملFast method for inverse determination of optical parameters from two measured signals.
Solving inverse problems requires multiple forward calculations of measured signals. We present a fast method combining graphic processing unit-accelerated Monte Carlo simulations of individual photons and a new perturbation scheme for a 300-fold speedup in comparison to conventional CPU-based approaches. The method allows rapid calculations of the diffuse reflectance and transmittance signals ...
متن کاملDetermination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression
A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...
متن کاملApplication of the Ratio Derivative Method in Quantitative Analysis of Samples Dyed with Ternary Dye Mixtures
In this study, a derivative method is applied for the determination of dye concentration in fabrics dyed with tricomponent dye mixtures. The reflectance of spectra of the samples were recorded between 400 and 700 nm. Initially, the obtained (K/S) spectra were divided by the spectrum of a standard sample dyed with two of the components in the ternary mixture and the derivative spectra were calcu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 14 16 شماره
صفحات -
تاریخ انتشار 2006