The influence of laser pulse duration and energy on ICP-MS signal intensity, elemental fractionation, and particle size distribution in NIR fs-LA-ICP-MS.
نویسندگان
چکیده
Laser parameters, typically wavelength, pulse width, irradiance, repetition rate, and pulse energy, are critical parameters which influence the laser ablation process and thereby influence the LA-ICP-MS signal. In recent times, femtosecond laser ablation has gained popularity owing to the reduction in fractionation related issues and improved analytical performance which can provide matrix-independent sampling. The advantage offered by fs-LA is due to shorter pulse duration of the laser as compared to the phonon relaxation time and heat diffusion time. Hence the thermal effects are minimized in fs-LA. Recently, fs-LA-ICP-MS demonstrated improved analytical performance as compared to ns-LA-ICP-MS, but detailed mechanisms and processes are still not clearly understood. Improvement of fs-LA-ICP-MS over ns-LA-ICP-MS elucidates the importance of laser pulse duration and related effects on the ablation process. In this study, we have investigated the influence of laser pulse width (40 fs to 0.3 ns) and energy on LA-ICP-MS signal intensity and repeatability using a brass sample. Experiments were performed in single spot ablation mode as well as rastering ablation mode to monitor the Cu/Zn ratio. The recorded ICP-MS signal was correlated with total particle counts generated during laser ablation as well as particle size distribution. Our results show the importance of pulse width effects in the fs regime that becomes more pronounced when moving from femtosecond to picosecond and nanosecond regimes.
منابع مشابه
The effect of laser pulse duration on ICP-MS signal intensity, elemental fractionation, and detection limits in fs-LA-ICP-MS
We investigated the role that pulse width has on the analytical capabilities of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), specifically in the range of 40 fs to 300 ps. Three main results of LA-ICP-MS were examined: signal intensity or sensitivity, elemental fractionation or that the ablated aerosol is representative of the bulk, and detection limits of various ele...
متن کاملThe effect of ultrafast laser wavelength on ablation properties and implications on sample introduction in inductively coupled plasma mass spectrometry.
We investigated the role of femtosecond (fs) laser wavelength on laser ablation (LA) and its relation to laser generated aerosol counts and particle distribution, inductively coupled plasma-mass spectrometry (ICP-MS) signal intensity, detection limits, and elemental fractionation. Four different NIST standard reference materials (610, 613, 615, and 616) were ablated using 400 nm and 800 nm fs l...
متن کاملLaser Ablation ICP-MS: particle size-dependent isotopic fractionation of copper in laser-generated aerosols
Laser induced isotopic fractionation Previous studies of laser ablation (LA) MC-ICP-MS analysis of Cu metal and sulphides showed reduced Cu/Cu ratios compared to solution nebulisation MC-ICP-MS of the same samples [1]. The fractionation of about 30ε (parts per 10,000) was reproduced repeatedly and observed, to a smaller degree, for Ag and Sb also. This deviation, which was attributed largely to...
متن کاملIron isotope composition of particles produced by UV-femtosecond laser ablation of natural oxides, sulfides, and carbonates.
The need for femtosecond laser ablation (fs-LA) systems coupled to MC-ICP-MS to accurately perform in situ stable isotope analyses remains an open question, because of the lack of knowledge concerning ablation-related isotopic fractionation in this regime. We report the first iron isotope analysis of size-resolved, laser-induced particles of natural magnetite, siderite, pyrrhotite, and pyrite, ...
متن کاملA new laser ablation system for quantitative analysis of solid samples with ICP-MS.
The laser ablation (LA) method is an effective technique for quantitative analysis. In the present work, a new LA system was developed for the high-sensitivity analysis of metal materials using inductively coupled plasma mass spectrometry (ICP-MS). This system consists of a high-frequency Q-switched laser and 2 scanning mirrors for scanning the ablation spot in an adequately large area of the s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical atomic spectrometry
دوره 28 شماره
صفحات -
تاریخ انتشار 2013