Measuring the current in the neutral-grounding resistor is needed for monitoring resistance-grounded three phase transformers. This current is limited to hundreds of amperes in case of a fault, and are almost negligible otherwise. The current transformer that senses the current must be rated for the fault conditions, thus it is difficult to obtain a precise measurement of the current when there is not a ground-fault in the system. In this paper we propose a computer-based method for filtering the output of the current transformer and improving its accuracy for small currents. This processing is complicated, as the amount of noise is very high, and this noise is strongly correlated with the useful signal. We propose to use Kalman filtering, based on a model of the system, and augment the state of this model with a shaping filter, whose frequency response, when fed with white Gaussian noise, reproduces our measurements of the ambient noise. In particular, since the Power Spectral Density (PSD) of the noise changes with time, we propose to use a possibilistic description of the PSD of the noise, and search for a model whose PSD is between the soft margins defined by the possibilistic model. We will use a state-space based representation and a genetic algorithm, guided by a fuzzy fitness function, for evolving the shaping filter that best matches the ambient noise. The proposed method has been evaluated with field data captured at a 130KV substation transformer at La Corredoria (Asturias, Spain).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

Discrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method

The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...

متن کامل

Impacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect

this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutra...

متن کامل

A UWB Transformer-C Orthonormal State Space Band-Reject Filter in 0.13 μm CMOS

An RF passive orthonormal ladder filter using transformers is presented, where the output is obtained from a linear, weighted combination of the voltages or currents at predetermined nodes or branches. With this topology, arbitrary rational transfer functions can be mapped onto silicon. Key features of this single-input, multiple-output (SIMO) topology include low-pass to band-pass/reject trans...

متن کامل

Effect of transformer symmetry on intrabody communication channel measurements using grounded instruments

Transformers with one winding terminal symmetrical with respect to ground (capacitances between their terminals and ground are the same) are referred to as balun transformers, and are often used for decoupling in the measurements of the intrabody communication (IBC) system transmission characteristics. We measured IBC system amplitude and phase transmission characteristics using three types of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010