The Monitoring of Power System Events on Transmission and Distribution Level by the Use of Phasor Measurement Units (pmu)

نویسندگان

  • Josef TLUSTY
  • Andrew KASEMBE
  • Zdenek MULLER
  • Jan SVEC
  • Tomas SYKORA
  • Antonin POPELKA
چکیده

Large power system disturbances and their consequences, represent a challenging problem for the power industry and especially for the network system operators, the ones who are responsible for the network operation at large, its security and reliability. This fact has reinforced interest in the new generation of monitoring systems with the aim to gain if possible a precise and maximum knowledge about those disturbances and their impact. Most of these severe events with impact on the entire system typically occur in or near the transmission network and are therefore best monitored at transmission system level. This puts great demands on the equipments and in general restricts the use of the data since it becomes property of the transmission system operator. Synchronized Phasor Measurement System has emerged as a powerful tool to improve power systems performance and reliability and fault localization possibility. Typical example of fault event that occurred in the transmission system and which was well registered by Phasor Measurement Units (PMU) that are installed in the distribution system will be shown in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Placement of Phasor Measurement Units to Maintain CompleteObservability Considering Maximum Reliability by Non-dominated Sorting Genetic Algorithm-II (NSGA-II)

Ever-increasing energy demand has led to geographic expansion of transmission lines and their complexity. In addition, higher reliability is expected in the transmission systemsdue to their vital role in power systems. It is very difficult to realize this goal by conventional monitoring and control methods. Thus, phasor measurement units (PMUs) are used to measure system parameters. Although in...

متن کامل

Optimal Placement of Phasor Measurement Units in Khorasan Network Using a Hybrid Intelligent Technique

In this paper, an efficient and comprehensive hybrid intelligent technique for the optimal placement of phasor measurement units (PMUs) is proposed to minimize the number of PMU installation subjected to full network observability. Three main purposes of PMUs output synchronous measurements are monitoring, control, and protection of power system. We have combined Binary Imperialistic Competitio...

متن کامل

Presenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units

In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...

متن کامل

Online Inertia Constant and Thévenin Equivalent Estimation Using PMU Data

In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009