Different effects of femoral and tibial rotation on the different measurements of patella tilting: An axial computed tomography study
نویسندگان
چکیده
BACKGROUND The various measurements of patellar tilting failed to isolate patellar tilting from the confounding effect of its neighboring bone rotation (femoral and tibial rotation) in people sustaining patellofemoral pain (PFPS). Abnormal motions of the tibia and the femur are believed to have an effect on patellofemoral mechanics and therefore PFPS. The current work is to explore the various effects of neighboring bone rotation on the various measurements of patellar tilting, through an axial computed tomography study, to help selecting a better parameter for patella tilting and implement a rationale for the necessary intervention at controlling the limb alignment in the therapeutic regime of PFPS. METHODS Forty seven patients (90 knees), comprising of 34 females and 11 males, participated in this study. Forty five knees, from randomly selected sides of bilaterally painful knees and the painful knees of unilaterally painful knees, were enrolled into the study. From the axial CT images in the subject knees in extension with quadriceps relaxed, the measurements of femoral rotation, tibial rotation, femoral rotation relative to tibia, and 3 parameters for patella tilting were obtained and analyzed to explore the relationship between the different measurements of patella tilt angle and the measurements of its neighboring bone rotation (femoral, tibial rotation, and femoral rotation relative to tibia). RESULTS The effect of femoral, tibial rotation, and femoral rotation relative to tibia on patella tilting varied with the difference in the way of measuring the patella tilt angle. Patella tilt angle of Grelsamer increased with increase in femoral rotation, and tibial rotation. Patella tilt angle of Sasaki was stationary with change in femoral rotation, tibial rotation, or femoral rotation relative to tibia. While, modified patella tilt angle of Fulkerson decreased with increase in femoral rotation, tibial rotation, or femoral rotation relative to tibia. CONCLUSION The current study has demonstrated various effects of regional bony alignment on the different measurements of the patellar tilt. And the influence of bony malalignment on the patellar tilt might draw a clinical implication that patellar malalignment can not be treated, separately, independent of the related limb alignment. This clinical implication has to be verified by further works, with a comprehensive evaluation of the various treatments of patellar malalignment.
منابع مشابه
Malrotation causing patellofemoral complications after total knee arthroplasty.
Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with...
متن کاملThe rotational alignment of the lower limbs in recurrent dislocation of the patella.
The rotational alignment tヲfthe lovver limbs of 24 patients who developed r巴currentdislocation of the patella were measured by means of computed axial tomography. The femoral anteversion and the external rotation of the knee joint of these patients respectively showed 31.9土15.2° and 9.2土6.8° on the average. These figures were significantly larger than those of the control. The average external ...
متن کاملProsthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations
BACKGROUND Clinical consequences of alignment errors in total knee replacement (TKR) have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components' relative positi...
متن کاملHow to Minimize Rotational Conflict between Femoral & Tibial Component in Total Knee Arthroplasty: The Use of Femoro-Tibial Axial Synchronizer (Linker)
PURPOSE The purpose of this study was to investigate the correlation between rotational axes of femur and tibia with the use of Linker. MATERIALS AND METHODS This study was carried out from August 2009 to February 2010 on 54 patients (106 knees), who were diagnosed with simultaneous bilateral total knee arthroplasty. With the use of postoperative computed tomography scans, it was investigated...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Orthopaedic Surgery and Research
دوره 3 شماره
صفحات -
تاریخ انتشار 2008