Accuracy of bedside glucose measurement from three glucometers in critically ill patients.

نویسندگان

  • Cornelia W E Hoedemaekers
  • Jacqueline M T Klein Gunnewiek
  • Marieke A Prinsen
  • Johannes L Willems
  • Johannes G Van der Hoeven
چکیده

OBJECTIVE Implementation of strict glucose control in most intensive care units has resulted in increased use of point-of-care glucose devices in the intensive care unit. The aim of this study was to determine the reliability of point-of-care testing glucose meters among critically ill patients under intensive insulin treatment. DESIGN Prospective observational study. PATIENTS Intensive care unit and non-intensive care unit patients in a tertiary care teaching hospital. MEASUREMENTS A glucose oxidase method was used to validate the point-of-care testing devices. Three different point-of-care testing devices, Accu-Chek Sensor (Roche Diagnostics), Precision (Abbott Diagnostics), and HemoCue were tested. Glucose measurements were performed in duplicate by an experienced technician under standardized conditions in the hospital's laboratory, using arterial (intensive care unit patients) and arterial or venous (non-intensive care unit patients) heparinized whole blood samples. MAIN RESULTS A strong correlation was found between the glucose oxidase method and the Accu-Chek device (r = .9596, p < 0.001). Mean absolute difference between the glucose oxidase and Accu-Chek was -0.32 mmol/L (95% confidence interval -0.84 to 1.48 mmol/L). Using the International Organization for Standardization (ISO) criteria, 27 of 197 samples (13.7%) were inaccurate. In all samples that failed to meet the ISO criteria, glucose values measured by the Accu-Chek device were higher compared with the glucose oxidase method. In another set of experiments among intensive care unit patients, strong positive correlations were also found between the other point-of-care testing devices and the glucose oxidase method. However, paired samples from Accu-Chek, HemoCue, and Precision failed the ISO criteria in 9 of 82 (11.0%), 4 of 82 (4.9%), and 11 of 82 (13.4%) of cases, respectively. In non-intensive care unit patients paired samples from Accu-Chek, HemoCue, and Precision failed the ISO criteria in 3 of 120 (2.5%), 11 of 120 (9.2%), and 16 of 120 (13.3%) cases, respectively. CONCLUSIONS Under standardized conditions, glucose results from three point-of-care testing devices were inaccurate in both intensive care unit and non-intensive care unit patients. Among intensive care unit patients, inaccurate glucose readings were most frequently falsely elevated, resulting in misinterpretation of high glucose values with subsequent inappropriate insulin administration or masking of true hypoglycemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inaccuracy of Venous Point-of-Care Glucose Measurements in Critically Ill Patients: A Cross-Sectional Study

INTRODUCTION Current guidelines and consensus recommend arterial and venous samples as equally acceptable for blood glucose assessment in point-of-care devices, but there is limited evidence to support this recommendation. We evaluated the accuracy of two devices for bedside point-of-care blood glucose measurements using arterial, fingerstick and catheter venous blood samples in ICU patients, a...

متن کامل

Blood glucose control in the intensive care unit: discrepancy between belief and practice

A survey among pediatric intensive care physicians showed that a great disparity exists between physicians' beliefs regarding hyperglycemia in critically ill patients and their daily practices to screen and treat hyperglycemia. One of the most prominent reasons for hesitating to implement tight glycemic control is the fear of evoking iatrogenic hypoglycemia. Results from ongoing and future stud...

متن کامل

Bedside Glucose Monitoring—Is it Safe? A New, Regulatory-Compliant Risk Assessment Evaluation Protocol in Critically Ill Patient Care Settings*

OBJECTIVES New data have emerged from ambulatory and acute care settings about adverse patient events, including death, attributable to erroneous blood glucose meter measurements and leading to questions over their use in critically ill patients. The U.S. Food and Drug Administration published new, more stringent guidelines for glucose meter manufacturers to evaluate the performance of blood gl...

متن کامل

Blood glucose measurements in arterial blood of intensive care unit patients submitted to tight glycemic control: agreement between bedside tests.

BACKGROUND Implementing tight glycemic control (TGC) in intensive care unit (ICU) patients requires accurate blood glucose (BG) monitoring. We evaluated the performance of two commercially available bedside glucometers, Accu-Chek and HemoCue, in patients admitted to the ICU and in whom TGC was applied. METHODS Thirty-seven adult ICU patients were prospectively included. During 48 hours, BG wa...

متن کامل

A new tracheostomy procedure.

1 Finkielman JD, Oyen LJ, Afessa B. Agreement between bedside blood and plasma glucose measurement in the ICU setting. Chest 2005; 127:1749–1751 2 Atkin SH, Dasmahapatra A, Jaker MA, et al. Fingerstick glucose determination in shock. Ann Intern Med 1991; 114:1020–1024 3 Maser RE, Butler MA, DeCherney GS. Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 36 11  شماره 

صفحات  -

تاریخ انتشار 2008