The Reliability of Electromyographic Normalization Methods for Cycling Analyses

نویسندگان

  • Jonathan Sinclair
  • Paul John Taylor
  • Jack Hebron
  • Darrell Brooks
  • Howard Thomas Hurst
  • Stephen Atkins
چکیده

Electromyography (EMG) is normalized in relation to a reference maximum voluntary contraction (MVC) value. Different normalization techniques are available but the most reliable method for cycling movements is unknown. This study investigated the reliability of different normalization techniques for cycling analyses. Twenty-five male cyclists (age 24.13 ± 2.79 years, body height 176.22 ± 4.87 cm and body mass 67.23 ± 4.19 kg, BMI = 21.70 ± 2.60 kg·m-1) performed different normalization procedures on two occasions, within the same testing session. The rectus femoris, biceps femoris, gastrocnemius and tibialis anterior muscles were examined. Participants performed isometric normalizations (IMVC) using an isokinetic dynamometer. Five minutes of submaximal cycling (180 W) were also undertaken, allowing the mean (DMA) and peak (PDA) activation from each muscle to serve as reference values. Finally, a 10 s cycling sprint (MxDA) trial was undertaken and the highest activation from each muscle was used as the reference value. Differences between reference EMG amplitude, as a function of normalization technique and time, were examined using repeated measures ANOVAs. The test-retest reliability of each technique was also examined using linear regression, intraclass correlations and Cronbach's alpha. The results showed that EMG amplitude differed significantly between normalization techniques for all muscles, with the IMVC and MxDA methods demonstrating the highest amplitudes. The highest levels of reliability were observed for the PDA technique for all muscles; therefore, our results support the utilization of this method for cycling analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface Electromyographic Assessment of Swallowing Function

The reliability of surface electromyographic (sEMG) variables during swallowing determines the potential usefulness of these measures in swallowing assessment and treatment. This study aimed to establish the reliability of the sEMG measures of the swallowing function of muscles during different swallowing conditions in healthy young and old volunteers. Two groups of volunteers (24 older adults,...

متن کامل

A Reliability of Electromyographic Normalization Methods for the Infraspinatus Muscle in Healthy Subjects

The purpose of this study was to examine the test-retest reliability of normalization methods for the infraspinatus muscle in a group of healthy subjects. Twelve healthy subjects (male=8, female=4) performed the maximal voluntary isometric contraction (MVIC) with examiner`s resistance, MVIC with a digital tension-meter (MVIC-DT), and sub-MVIC methods. Surface electromyography (EMG) signals were...

متن کامل

Reliability of electromyographic normalization methods for evaluating the hip musculature.

The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum volunta...

متن کامل

Electromyographic (EMG) normalization method for cycle fatigue protocols.

PURPOSE To determine the most effective electromyographic (EMG) normalization method for cycling fatigue protocols. METHODS Ten healthy subjects performed two 5-s isometric knee extension maximal voluntary contractions (MVC) at a knee joint angle of 60 degrees, two fixed cycle pedal contraction at knee joint angles of 60 degrees (60 degrees A) and 108 degrees (108 degrees A), and a dynamic si...

متن کامل

The test-retest reliability of the onset of core and vasti electromyographic activity while ascending and descending stairs in healthy controls and patellofemoral pain patients

AbstractBackgroundentity. It is hypothesized to result from abnormal patellar tracking caused by altered motorcontrol. Deficit in neuromotor control of the core may be a remote contributing factor to thedevelopment of PFP. Application of reliable EMG measures would be helpful to handle thistheory. Therefore, the purpose of this study was to determine the test-retest reliability of thecore and v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2015