Towards patient-specific modeling of mitral valve repair: 3D transesophageal echocardiography-derived parameter estimation

نویسندگان

  • Fan Zhang
  • Jingjing Kanik
  • Tommaso Mansi
  • Ingmar Voigt
  • Puneet Sharma
  • Razvan Ioan Ionasec
  • Lakshman Subrahmanyan
  • Ben A. Lin
  • Lissa Sugeng
  • David D. Yuh
  • Dorin Comaniciu
  • James S. Duncan
چکیده

Transesophageal echocardiography (TEE) is routinely used to provide important qualitative and quantitative information regarding mitral regurgitation. Contemporary planning of surgical mitral valve repair, however, still relies heavily upon subjective predictions based on experience and intuition. While patient-specific mitral valve modeling holds promise, its effectiveness is limited by assumptions that must be made about constitutive material properties. In this paper, we propose and develop a semi-automated framework that combines machine learning image analysis with geometrical and biomechanical models to build a patient-specific mitral valve representation that incorporates image-derived material properties. We use our computational framework, along with 3D TEE images of the open and closed mitral valve, to estimate values for chordae rest lengths and leaflet material properties. These parameters are initialized using generic values and optimized to match the visualized deformation of mitral valve geometry between the open and closed states. Optimization is achieved by minimizing the summed Euclidean distances between the estimated and image-derived closed mitral valve geometry. The spatially varying material parameters of the mitral leaflets are estimated using an extended Kalman filter to take advantage of the temporal information available from TEE. This semi-automated and patient-specific modeling framework was tested on 15 TEE image acquisitions from 14 patients. Simulated mitral valve closures yielded average errors (measured by point-to-point Euclidean distances) of 1.86 ± 1.24 mm. The estimated material parameters suggest that the anterior leaflet is stiffer than the posterior leaflet and that these properties vary between individuals, consistent with experimental observations described in the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence.

OBJECTIVES This study sought to assess the use of real-time (RT) 3-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) in the evaluation of post-operative mitral valve dehiscence. BACKGROUND Mitral valve replacement or repair may be complicated by post-operative dehiscence of the valve or annuloplasty ring resulting in clinically significant mitral regurgitation or hemol...

متن کامل

Two and three dimensional echocardiography for pre-operative assessment of mitral valve regurgitation

Mitral regurgitation may develop when the leaflets or any other portion of the apparatus becomes abnormal. As the repair techniques for mitral valve disease evolved, so has the need for detailed and accurate imaging of the mitral valve prior to surgery in order to better define the mechanism of valve dysfunction and the severity of regurgitation. In patients with significant mitral valve diseas...

متن کامل

Role of 3D Echocardiography in Cardiac Surgery: Strengths and Limitations

PURPOSE OF REVIEW This review aims to highlight the general and specific strengths and limitations of intraoperative 3D echocardiography. This article explains the value of real-time three-dimensional transesophageal echocardiography (RT 3D TEE) during cardiac surgery and cardiac interventions. RECENT FINDINGS Recently published recommendations and guidelines include the use of RT 3D TEE. RT ...

متن کامل

Real-time 3-dimensional transesophageal echocardiography: precise evaluation of a rocking mitral annuloplasty ring.

A 48-year-old man with a medical history of hypertension was admitted with acute dyspnea and pyrexia. Echocardiographic examination revealed a dilated and volumeoverloaded left ventricle and severe mitral regurgitation due to ruptured chordae tendinae resulting in posterior leaflet prolapse. Blood cultures were negative. The patient was treated with antibiotics considering that he had a chest i...

متن کامل

Three-dimensional transesophageal echocardiography: diagnosing intraoperative pulmonary artery thrombus.

A 61-year-old patient with the diagnosis of acute heart failure based on severe mitral valve insufficiency due to chordae rupture was scheduled for surgery. Intraoperatively, a standard two-dimensional transesophageal echocardiogram (2D-TEE) examination, revealed severe mitral valve regurgitation due to a prolaps with chordal rupture and an echo dense structure in the pulmonary artery (PA). Bec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image analysis

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2017