Hemodynamic monitoring utilizing transesophageal echocardiography: the relationships among pressure, flow, and function.
نویسندگان
چکیده
Abbreviations: A wave late-filling wave; CW continuouswave; dP/dtmax positive maximum first derivative of pressure, corrected for time; Ea arterial elastance; E/A ratio of the early and rapid-filling wave to the late-filling wave; E wave early and rapid-filling wave; LA left atrium atrial; LAP left atrial pressure; LV left ventricle/ventricular; LVEDA left ventricular end-diastolic area; LVEDP left ventricular end-diastolic pressure; LVEDV left ventricular end-diastolic volume; PCWP pulmonary capillary wedge pressure; PW pulsed-wave; PWR cardiac power; RV right ventricle/ventricular; RVOT right ventricular outflow tract; SV stroke volume; TDI tissue Doppler imaging; TEE transesophageal echocardiography; VTI velocity-time integral
منابع مشابه
Doppler echocardiography in shocked patients.
PURPOSE OF REVIEW To reiterate the necessity of integrating echocardiography in the management of shocked patients and to propose a step-by-step functional evaluation of hemodynamics proven to optimize hemodynamic monitoring and to adapt the treatment. RECENT FINDINGS Echocardiography has become the cornerstone to hemodynamic monitoring. By providing real-time images, echocardiography has the...
متن کاملEvaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring
Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...
متن کاملHemodynamic monitoring using a single-use indwelling transesophageal echocardiography probe in an unstable patient after open-heart surgery
BACKGROUND Hemodynamic monitoring is frequently needed in ventilated patients with unstable hemodynamics after open-heart surgery. Novel miniaturized single-use transesophageal echocardiographic probe has been scarcely used in this clinical setting. CASE PRESENTATION A patient who underwent a scheduled open-heart surgery developed a ventilator-associated pneumonia and was referred to the inte...
متن کاملAcute hemodynamic changes of pressure-controlled inverse ratio ventilation in the adult respiratory distress syndrome. A transesophageal echocardiographic and Doppler study.
Twelve patients with the adult respiratory distress syndrome were included in this study and evaluated by transesophageal echocardiography and Doppler, assessing right and left ventricular intracardiac blood flow alterations with progressive increase of inspiration-to-expiration (I-E) ratios. Whereas midpulmonary artery flow parameters did not show any change, early left ventricular filling dem...
متن کاملWhat's New in Critical Illness and Injury Science? The continued search for the ideal hemodynamic monitoring device: Spending ourselves in a worthy cause and coming up short
© 2017 International Journal of Critical Illness and Injury Science | Published by Wolters Kluwer Medknow The continued search for the ideal hemodynamic monitoring tool continues. Over time, the medical community has endeavored to identify correlates of hemodynamic status and resultant responses to volume expansion. Historically, we have pursued the use of physical examination alone (jugular he...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 127 1 شماره
صفحات -
تاریخ انتشار 2005