Simultaneous measurements of knee motion using an optical tracking system and radiostereometric analysis (RSA)
نویسندگان
چکیده
BACKGROUND AND PURPOSE Invasive methods are more reproducible and accurate than non-invasive ones when it comes to recording knee kinematics, but they are usually less accessible and less safe, mainly due to risk of infection. For this reason, non-invasive methods with passive markers are widely used. With these methods, varying marker sets based on a number of single markers, or sets of markers, known as clusters, are used to track body segments. We compared one invasive method--radiostereometric analysis--with a non-invasive method, an optical tracking system with 15 skin-mounted markers. METHODS 9 subjects (10 knees) were investigated simultaneously with a dynamic RSA system and a motion-capture system while performing an active knee extension. RESULTS For flexion/extension, there was good agreement on an individual basis and at the group level. For internal/external rotation, the group mean was fairly similar, up to 25 degrees of flexion. Recordings of abductions and/or adductions revealed a systematic mean difference of 2-4 degrees during the range of flexion measured. The correlation between the 2 methods in the horizontal and frontal planes was poor. INTERPRETATION Our skin-marker model provided reliable data for flexion/extension. Recordings of internal/external rotation and abduction/adduction were less accurate on an individual basis than at the group level, most probably due to soft-tissue motion and the presence of small true motion in these planes.
منابع مشابه
Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis.
We obtained simultaneous measurements of sagittal knee laxity in 12 consecutive patients after reconstruction of the anterior cruciate ligament (ACL), using the Stryker laxity tester and radiostereometric analysis (RSA). The mean anteroposterior (AP) displacement when a 90 N load was applied in both directions was 5.3 +/- 2.7 mm with RSA and 9.8 +/- 1.6 mm with the external device (p < 0.001). ...
متن کاملAccuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion
BACKGROUND Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS To assess ...
متن کاملComparative accuracy of radiostereometric and optical tracking systems.
This study aims to quantify and compare the accuracy of traditional radiostereometric analysis (RSA), fluoroscopic RSA (fRSA), and optical tracking systems. Three phantoms were constructed, each having three stainless steel spheres and three reflective markers. One phantom was mounted to the base of a precision cross-slide table, one to the base of a precision rotation table, and the third was ...
متن کاملValidation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data
OBJECTIVES Static radiostereometric analysis (RSA) using implanted markers is considered the most accurate system for the evaluation of prosthesis migration. By using CT bone models instead of markers, combined with a dynamic RSA system, a non-invasive measurement of joint movement is enabled. This method is more accurate than current 3D skin marker-based tracking systems. The purpose of this s...
متن کاملTourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motion
BACKGROUND AND PURPOSE Although a tourniquet may reduce bleeding during total knee replacement (TKA), and thereby possibly improve fixation, it might also cause complications. Migration as measured by radiostereometric analysis (RSA) can predict future loosening. We investigated whether the use of a tourniquet influences prosthesis fixation measured with RSA. This has not been investigated prev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 82 شماره
صفحات -