A proposed DAQ system for a calorimeter at the International Linear Collider
نویسنده
چکیده
This note describes R&D to be carried out on the data acquisition system for a calorimeter at the future International Linear Collider. A generic calorimeter and data acquisition system is described. Within this framework modified designs and potential bottlenecks within the current system are described. Solutions leading up to a technical design report will to be carried out within CALICE-UK groups.
منابع مشابه
A DAQ System for Linear Collider TPC Prototypes based on the ALEPH TPC Electronics
Within the international studies of a high energy linear electron positron collider, several groups are developing and testing prototypes for a Linear Collider TPC. This detector is planned to be used as a central part in the tracking system of a detector at such a machine. In this note we describe a DAQ system, which has been developed for the use in tests of TPC prototypes. It is based on ele...
متن کاملStatus of the CALICE DAQ system
A data acquisition (DAQ) system is described which will be used for the next generation of prototype calorimeters using particle flow algorithms for the International Linear Collider (ILC). The design is sufficiently generic and scalable such that it should have numerous applications either for ILC detectors or elsewhere within high energy physics in general. The DAQ system will be implemented ...
متن کاملThe Tail-Catcher/Muon Tracker for the CALICE Test Beam
The CALICE (CAlorimeter for the Linear Collider with Electrons) collaboration [1] plans to examine several technology and geometry options for electromagnetic and hadronic calorimetry at the proposed International Linear Collider. Since in many geometries the total material thickness of the calorimeter is too little to fully contain highly energetic hadronic showers, it is important to gain a g...
متن کاملMonte Carlo Study of a Luminosity Detector for the International Linear Collider ∗
This paper presents the status of Monte Carlo simulation of one of the luminosity detectors considered for the future e + e − International Linear Collider (ILC). The detector consists of a tungsten/silicon sandwich calorimeter with pad readout. The study was performed for Bhabha scattering events assuming a zero crossing angle for the beams.
متن کاملSilicon Detectors for the Large Prototype TPC test setup at DESY
The Linear Collider TPC collaboration constructed a Large Prototype TPC (LPTPC) which is now installed at the EUDET facility, in DESY. The SiLC-collaboration (Silicon for the Linear Collider) will install position sensitive silicon strip sensors outside the field cage of the LPTPC, to provide precise tracking information. The data acquisition system (DAQ) is an adapted CMS readout system. The s...
متن کامل