Prevention and management of external fixator pin track sepsis
نویسندگان
چکیده
Pin track-associated complications are almost universal findings with the use of external fixation. These complications are catastrophic if it leads to the failure of the bone-pin interface and could lead to pin loosening, fracture non-union and chronic osteomyelitis. Strategies proposed for the prevention and management of pin track complications are diverse and constantly changing. Prevention of external fixation pin track infection is a complex and ongoing task that requires attention to detail, meticulous surgical technique and constant vigilance.
منابع مشابه
The effect of HIV infection on the incidence and severity of circular external fixator pin track sepsis: a retrospective comparative study of 229 patients
Pin track sepsis is a common complication of circular external fixation. HIV status has been implicated as an independent risk factor for the development of pin track infection and has been cited as a reason not to attempt complex limb reconstruction in HIV-positive patients. This retrospective review of patients treated with circular external fixators looked at the incidence of pin track sepsi...
متن کاملTreatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?
Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...
متن کاملTreatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails
Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...
متن کاملModified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures
High-energy tibial plateau fractures associated with severe soft tissue injury are difficult to manage. The risk of wound complications following open reduction and internal fixation is notably high owing to extensive soft tissue dissection. Alternatively, application of hybrid external fixator minimizes soft tissue dissection and provides adequate fracture stabilization to allow early range of...
متن کاملConversion of external fixation to internal fixation in a non-acute, reconstructive setting: a case series
The aim of the study is to determine the outcomes in patients who underwent conversion from an external fixator to an internal fixation device. This is a retrospective review of 18 patients (24 limbs) who underwent conversion from external to internal fixation. The patients had external fixators applied for traumatic bone defects or congenital deformities. Conversion to internal fixation was pe...
متن کامل