Treatment planning methodology for the Miami Multichannel Applicator following the American Brachytherapy Society recently published guidelines: the Lahey Clinic experience

نویسندگان

  • Ileana Iftimia
  • Eileen T. Cirino
  • Herbert W. Mower
  • Andrea B. McKee
چکیده

The objective of this study was to develop a standardized procedure from simulation to treatment delivery for the multichannel Miami applicator, in order to increase planning consistency and reduce errors. A plan is generated prior to the 1st treatment using the CT images acquired with the applicator in place, and used for all 3 fractions. To confirm the application placement before each treatment fraction, an AP image is acquired and compared with the AP baseline image taken at simulation. A preplanning table is generated using the EBRT doses and is used to compute the maximum allowable D2cc for bladder, rectum, and sigmoid, and the mean allowable dose for the upper vaginal wall per HDR brachytherapy fraction. These data are used to establish the criteria for treatment planning dose optimization. A step-by-step treatment planning approach was developed to ensure appropriate coverage for the tumor (D90 > 100% prescribed dose of 700 cGy/fraction) and the uninvolved vaginal surface (dose for the entire treatment length > 600 cGy/fraction), while keeping the organs at risk below the tolerance doses. The equivalent dose 2 Gy (EQD2) tolerances for the critical structures are based on the American Brachytherapy Society (ABS) recently published guidelines. An independent second check is performed before the 1st treatment using an in-house Excel spreadsheet. This methodology was successfully applied for our first few cases. For these patients: the cumulative tumor dose was 74-79 EQD2 Gy10 (ABS recommended range 70-85); tumor D90 was >100% of prescribed dose (range 101%-105%); cumulative D2cc for bladder, rectum, and sigmoid were lower than the tolerances of 90, 75, and 75 EQD2 Gy3, respectively; cumulative upper vaginal wall mean dose was below the tolerance of 120 EQD2 Gy3; the second check agreement was within 5%. By using a standardized procedure the planning consistency was increased and all dosimetric criteria were met.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computed tomography-based treatment planning for high-dose-rate brachytherapy using the tandem and ring applicator: influence of applicator choice on organ dose and inter-fraction adaptive planning

Three dimensional planning for high-dose-rate (HDR) brachytherapy in cervical cancer has been highly recommended by consensus guidelines such as the American Brachytherapy Society (ABS) and the Groupe Européen de Curiethérapie - European Society for Radiotherapy and Oncology (GEC-ESTRO). In this document, we describe our experience with computed tomography (CT)-based planning using the tandem/r...

متن کامل

Advantages of inflatable multichannel endorectal applicator in the neo‐adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy

High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, r...

متن کامل

Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning

PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013