Evaluation of Fracture Resistance of Orthodontic Mini-implants in the Transmucosal Profile Region.
نویسندگان
چکیده
AIM This study sought to compare the fracture resistance of three trademarked orthodontic mini-implants in the transmucosal profile region. Thirty-six mini-implants of three different brands, separated into groups I, II and III, were tested. Each group consisted of 12 mini-implants of 6 mm in length. The mean diameter and length of the transmucosal profile of the mini-implants were 1.90 and 2.0 mm in group I, 1.77 and 1.0 mm in group II and 1.50 and 1.0 mm in group III, respectively. The tests were performed on a universal testing machine in compression mode, with a 2,000 kgf load, a speed of 4.0 mm per minute and a chisel-shaped active tip, which acted cross-sectionally on the transmucosal profile. Single-criterion analysis of variance was used to compare the three brands. A significance level of 5% and test power of 80% were adopted. The mean fracture resistance achieved by the mini-implants was 172.03 ± 25.59 N for group I, 162.35 ± 30.81 N for group II and 139.69 ± 42.99 N for group III. There was no statistically significant difference in mean fracture resistance among the tested mini-implant brands. CONCLUSION The transmucosal profile diameter does not seem to be a deciding factor in the choice of mini-implants to minimize the risk of fractures. CLINICAL SIGNIFICANCE Although being an in vitro study it is possible to believe that this new brand has a very satisfactory resistance to fracture and enables its use with great efficiency.
منابع مشابه
Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness
OBJECTIVE This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. METHODS Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal n...
متن کاملFracture strength of orthodontic mini-implants
Objective: This study aimed at evaluating the design and dimensions of five different brands of orthodontic mini-implants, as well as their influence on torsional fracture strength. Methods: Fifty mini-implants were divided into five groups corresponding to different manufactures (DEN, RMO, CON, NEO, SIN). Twenty-five mini-implants were subjected to fracture test by torsion in the neck and t...
متن کاملTitanium alloy orthodontic mini-implants: scanning electron microscopic and metallographic analyses.
Anchorage control is one of the determining factors of successful orthodontic mechanics. In mini-implants, fractures due to placement and removal have been related to implant design and titanium alloy quality. This study assessed the topography and microstructure of five brands of mini-implants (Neodent, SIN, Morelli, Conexao, Foresta Dent). Scanning electron microscopic analyses of the head, t...
متن کاملClinical indices for orthodontic mini-implants.
Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offe...
متن کاملInsertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.
PURPOSE Fracture of orthodontic mini-implants during insertion is a limiting factor for their clinical success. The purpose of this study was to determine the fracture potential of commonly used self-drilling orthodontic mini-implants when placed into simulated thick, dense mandibular bone. MATERIALS AND METHODS Six mini-implant systems were assessed for the potential for fracture (Aarhus, Me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2015