Interventional MRA using actively visualized catheters, TrueFISP, and real-time image fusion.

نویسندگان

  • Harald H Quick
  • Hilmar Kuehl
  • Gernot Kaiser
  • Dirk Hornscheidt
  • Krzysztof P Mikolajczyk
  • Stephanie Aker
  • Jörg F Debatin
  • Mark E Ladd
چکیده

An integrated system for performing interventional magnetic resonance angiography (MRA) with actively visualized instruments and real-time image fusion was implemented on a 1.5 T scanner. True fast imaging with steady precession (TrueFISP) imaging provided high acquisition speed paired with high signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the simultaneous visualization of active instruments and arterial morphology. The system enabled simultaneous image reconstruction and image postprocessing of multiple receiver channels, with subsequent image fusion display in real time. Optional interleaved image acquisition in two planes provided additional important information for biplanar instrument guidance. Various vascular interventions, including selective catheterization and subsequent selective MRA of the abdominal aorta, renal arteries, superior mesenteric artery (SMA), hepatic artery, and aortic arch, were performed on 10 pigs under MR guidance. In terms of instrument contrast, image acquisition, reconstruction, and fusion speed, the setup represents a powerful platform for performing interventional MRA procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-Enhanced Whole-Heart Coronary MRA at 1.5T in less than 5 minutes using Gradient Echo Interleaved EPI and double dose of Gd-DTPA

INTRODUCTION: Whole-heart coronary MRA [1] is a promising technique, however, it is challenging due to the relatively long data acquisition time on the order of 10-15 minutes. Gradient echo interleaved EPI (GRE-EPI) [2] can provide significant speed gain and has previously been reported for volume-targeted imaging at 1.5T [3, 4]. The purpose of this work was to optimize a GRE-EPI sequence for r...

متن کامل

Towards Guidance of Electrophysiological Procedures with Real-Time 3D Intracardiac Echocardiography Fusion to C-arm CT

This paper describes a novel method for improving the navigation and guidance of devices and catheters in electrophysiology and interventional cardiology procedures using volumetric data fusion. The clinical workflow includes the acquisition and reconstruction of CT data from a C-arm X-ray angiographic system and the real-time acquisition of volumetric ultrasound datasets with a new intracardia...

متن کامل

CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions

Digital subtracted angiography (DSA) remains the gold standard for diagnosis of cerebral vascular diseases and provides intraprocedural guidance. This practice involves extensive usage of x-ray and iodinated contrast medium, which can induce side effects. In this study, we examined the accuracy of 3-dimensional (3D) registration of magnetic resonance angiography (MRA) and DSA imaging for cerebr...

متن کامل

3D Time-of-Flight MRA Using Inversion Recovery TrueFISP

A major drawback of 3D time-of-flight (TOF) sequences is progressive saturation of inflowing spins along the slab direction, and a sufficient long TR or shaped excitation pulses are required to compensate for this. Here we present a new TOF technique based on a combination of selective inversion and 3D acquisition with TrueFISP. The stationary tissue is partially suppressed by the inversion pul...

متن کامل

An Integrated Visualization System for Surgical Planning and Guidance Using Image Fusion and Interventional Imaging

We present a software package which uniquely integrates several facets of image-guided medicine into a single portable, extendable environment. It provides capabilities for automatic registration, semiautomatic segmentation, 3D surface model generation, 3D visualization, and quantitative analysis of various medical scans. We describe its system architecture, wide range of applications, and nove...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2003