Lack of grading agreement among international hemostasis external quality assessment programs

نویسندگان

  • John D. Olson
  • Ian Jennings
  • Piet Meijer
  • Chantal Bon
  • Roslyn Bonar
  • Emmanuel J. Favaloro
  • Russell A. Higgins
  • Michael Keeney
  • Joy Mammen
  • Richard A. Marlar
  • Roland Meley
  • Sukesh C. Nair
  • William L. Nichols
  • Anne Raby
  • Joan C. Reverter
  • Alok Srivastava
  • Isobel Walker
چکیده

: Laboratory quality programs rely on internal quality control and external quality assessment (EQA). EQA programs provide unknown specimens for the laboratory to test. The laboratory's result is compared with other (peer) laboratories performing the same test. EQA programs assign target values using a variety of methods statistical tools and performance assessment of 'pass' or 'fail' is made. EQA provider members of the international organization, external quality assurance in thrombosis and hemostasis, took part in a study to compare outcome of performance analysis using the same data set of laboratory results. Eleven EQA organizations using eight different analytical approaches participated. Data for a normal and prolonged activated partial thromboplastin time (aPTT) and a normal and reduced factor VIII (FVIII) from 218 laboratories were sent to the EQA providers who analyzed the data set using their method of evaluation for aPTT and FVIII, determining the performance for each laboratory record in the data set. Providers also summarized their statistical approach to assignment of target values and laboratory performance. Each laboratory record in the data set was graded pass/fail by all EQA providers for each of the four analytes. There was a lack of agreement of pass/fail grading among EQA programs. Discordance in the grading was 17.9 and 11% of normal and prolonged aPTT results, respectively, and 20.2 and 17.4% of normal and reduced FVIII results, respectively. All EQA programs in this study employed statistical methods compliant with the International Standardization Organization (ISO), ISO 13528, yet the evaluation of laboratory results for all four analytes showed remarkable grading discordance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra- and interobserver analysis in the morphological assessment of early stage embryos during an IVF procedure: a multicentre study

BACKGROUND Quality control programs are necessary to maintain good clinical practice. Embryo grading has been described as one of the external quality assurance schemes. Although the evaluation of embryos is based on the assessment of morphological characteristics, considerable intra- and inter-observer variability has been described. In this multicentre study, the variability in the embryo eva...

متن کامل

بررسی کارایی و تکرار پذیری سیستم سیدنی در ارزیابی و درجه‌بندی گاستریت مزمن

  Background and Aim: Chronic gastritis is one of the most common gastrointestinal disorders and detection of its etiology especially Helicobacter pylori and risk factors of malignancy (atrophy and intestinal metaplasia) is, to a great extent, based on histological assessment. Therefore, a system which could sustain good reproducibility in reporting observations is very important. Today, the mo...

متن کامل

Accuracy of grading of urothelial carcinoma on urine cytology: an analysis of interobserver and intraobserver agreement.

BACKGROUND Urine samples of known urothelial carcinoma were independently graded by 3 pathologists with (MS, MR) and without (AO) fellowship training in cytopathology using a modified version of the 2004 2-tiered World Health Organization classification system. By measuring interobserver and intraobserver agreement among pathologists, compared with the gold standard of biopsy/resection, specime...

متن کامل

A systematic review of tension-free urethropexy for stress urinary incontinence: intravaginal slingplasty and the tension-free vaginal tape procedures.

Assessment of study quality The studies were graded as poor, average or good for internal and external validity. The grading for internal validity was based on an assessment of bias, confounding and the role of chance; the grading for external validity was based on the population, inclusion or exclusion criteria and follow-up. Each study was also assigned a level of evidence from I (highest) to...

متن کامل

Quality control for histological grading in breast cancer: an Italian experience.

Although the diagnostic criteria for histological grading in breast cancer have been improved by the introduction of the Nottingham/Tenovus classification, good results in terms of reproducibility are hard to obtain. The objective of this study was to validate a methodological protocol for external quality control. We assessed the intra- and interlaboratory reproducibility for grading score and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2018