Serial magnetic resonance imaging of hamstring anterior cruciate ligament autografts during the first year of implantation. A preliminary study.
نویسندگان
چکیده
A prospective, observational study was performed to document the serial changes in the magnetic resonance signal of devascularized, hamstring ACL autografts during the 1st year of implantation. Twenty-one ACL deficient knees (14 chronic, 7 acute) were reconstructed. Instability developed in five knees within the first 6 months of graft implantation (24%). Magnetic resonance examinations were performed at 1, 6, 12, 24, 36, and greater than 48 weeks postoperatively (repetition time 1500, echo delay time = 50). A total of 104 scans were reviewed (average, five per knee). The ACL graft was divided into four unequal size zones for analysis. The proximal, middle, and distal thirds of the intraarticular portion of the graft and the portion of the graft within the tibial tunnel were independently analyzed. The magnetic resonance signal in each portion of the graft was graded on a scale with (I) being a normal signal, (II) greater than 50% of the total volume of the graft having a normal signal, (III) less than 50% of the graft having a normal signal, and (IV) 100% of the graft having an increased signal. The increased magnetic resonance signal of the ACL graft was observed to be regionalized and confined to the distal two-thirds of the intraarticular portion of the graft. The portion of the graft exiting the femoral tunnel and within the tibial tunnel retained a normal magnetic resonance signal. The increases in magnetic resonance graft signal were time-dependent, became well established by 3 months, and remained unchanged at 1 year. The clinical outcome could not be predicted based on the magnetic resonance signal of the graft.
منابع مشابه
Revascularization of a human anterior cruciate ligament graft during the first two years of implantation.
The blood supplies of 45 unimpinged, human anterior cruciate ligament grafts were studied during the first 2 years of implantation. Grafts were defined as unimpinged by the low signal intensity of the graft observed on a sagittal proton density magnetic resonance scan. Magnetic resonance imaging with the intravenous contrast agent gadolinium diethylenetriamine pentacetic acid was used to evalua...
متن کاملOne-Year Serial Follow-up Magnetic Resonance Imaging Study of RigidFix for Femoral Fixation in Anterior Cruciate Ligament Reconstruction
Purpose To assess graft slippage at the site of femoral fixation by follow-up magnetic resonance imaging (MRI) after anterior cruciate ligament (ACL) reconstruction with a four-strand autogenous hamstring tendon using RigidFix (DePuy Mitek). Materials and Methods Twenty-one subjects diagnosed with ACL rupture underwent ACL reconstruction using hamstring autograft with the transtibial techniqu...
متن کاملBiologic and Mechanical Augmentation in Anterior Cruciate Ligament Reconstruction: Fibrin Clot Augmentation of 5-Strand Hamstring Autograft
Hamstring autografts in anterior cruciate ligament reconstruction have an excellent clinical track record, but some patients have hamstring tendons that yield grafts of smaller diameter, which has been shown to be a significant risk factor for worse outcomes and graft failure. Some authors have advocated augmentation with allograft in these patients. Tripling the semitendinosus yields a complet...
متن کاملDoes anatomic single-bundle ACL reconstruction using hamstring autograft produce anterolateral meniscal root tearing?
BACKGROUND To determine if tibial tunnel reaming during anatomic single-bundle anterior cruciate ligament (ACL) reconstruction using hamstring autograft can result in anterolateral meniscal root injury, as diagnosed by magnetic resonance imaging (MRI). METHODS A case series of 104 primary anatomic single-bundle ACL reconstructions using hamstring autograft was retrospectively reviewed. Pre- a...
متن کاملAutograft contamination during preparation for anterior cruciate ligament reconstruction.
BACKGROUND The autograft preparation process for anterior cruciate ligament reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of contamination of the bone-patellar tendon-bone and hamstring tendon autograft during preparation for anterior cruciate ligament reconstruction. METHODS A primary isolated reconstruction of the anterior ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of sports medicine
دوره 19 1 شماره
صفحات -
تاریخ انتشار 1991