Coronary hemodynamics of stent implantation after suboptimal and optimal balloon angioplasty.

نویسندگان

  • Michiel Voskuil
  • Rob A M van Liebergen
  • Mariano Albertal
  • Eric Boersma
  • Jan G P Tijssen
  • Patrick W Serruys
  • Jan J Piek
چکیده

OBJECTIVES This study was performed to evaluate hemodynamic alterations of stent implantation after Doppler flow-guided balloon angioplasty (BA). BACKGROUND There is controversy regarding the effect of stent implantation on coronary hemodynamics after suboptimal and optimal BA. METHODS A total of 523 of 620 patients underwent Doppler-guided BA in the setting of a multicenter study and were analyzed before and after additional stent implantation. Balloon angioplasty was considered optimal when the diameter stenosis (DS) was < or = 35% and coronary flow reserve (CFR) was >2.5 and suboptimal if these two criteria were not met. Coronary flow reserve was also measured in an angiographically normal artery to determine relative CFR. Patients were followed for 12 months to document major adverse cardiac events (MACE). RESULTS The main difference between patients with suboptimal BA (n = 195 [51%]) and optimal BA (n = 184 [49%]) was a more pronounced increase in baseline blood flow velocity (15 +/- 8 to 22 +/- 11 vs. 14 +/- 8 to 16 +/- 10 cm/s, p < 0.01). Coronary flow reserve improved after stent implantation in both patient groups, owing to a reduction in residual lumen obstruction, as determined by angiographic (%DS) and Doppler flow criteria (hyperemic blood flow velocity, relative CFR), and was associated with a decrease in MACE (16% vs. 7% in optimal BA group, p = 0.08; and 27% vs. 11% in suboptimal BA group, p = 0.007). CONCLUSIONS Stent implantation enhances CFR after suboptimal and optimal Doppler-guided BA, owing to a reduction in residual lumen obstruction-determined by angiographical and Doppler flow criteria-as the underlying mechanism for an improved clinical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized Comparison of Elective Stent Implantation and Coronary Balloon Angioplasty Guided by Online Quantitative Angiography and Intracoronary Doppler

Background—The purpose of this study was to compare long-term outcomes of coronary stenting in all lesions (elective stenting) or only in lesions with inadequate morphological and functional results after balloon angioplasty (guided PTCA). Methods and Results—Treatment of multivessel disease, with any lesion length and vessel size, was allowed provided that all lesions were suitable for stent i...

متن کامل

Is bare-metal stenting superior to balloon angioplasty for small vessel coronary artery disease? Evidence from a meta-analysis of randomized trials.

AIMS To compare, by meta-analytical techniques, the clinical impact of bare-metal stenting vs. balloon angioplasty for the treatment of lesions in small coronary arteries. METHODS AND RESULTS We included trials with random allocation and prospective comparison of angioplasty vs. stenting, reference vessel diameter<3 mm, and follow-up>or=6 months. Random effect odds ratios (OR) for death, myoc...

متن کامل

Balloon angioplasty for the treatment of coronary in-stent restenosis: immediate results and 6-month angiographic recurrent restenosis rate.

OBJECTIVES The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The opt...

متن کامل

Frequency and clinical significance of myocardial ischemia detected early after coronary stent implantation.

UNLABELLED A high number (30%-50%) of reversible defects have been detected early after coronary balloon angioplasty. Inadequate luminal enlargement despite a good angiographic appearance has been suggested as a possible mechanism of these perfusion abnormalities, and some reports have shown better coronary flow reserve after coronary stent implantation than after balloon dilatation. The primar...

متن کامل

Stent Optimization Using Adjunctive Balloon Dilatation in the Era of Second-Generation Drug-Eluting Stents

Percutaneous coronary intervention (PCI) using both balloon angioplasty and coronary stents has markedly reduced adverse cardiac events in patients with ischemic heart disease. Drug-eluting stents (DES) could further decrease the incidence of target vessel revascularization (TVR) to 5%–10% compared to bare-metal stents (BMS) or balloon angioplasty alone.1) Despite its clinical benefits, stent f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 39 9  شماره 

صفحات  -

تاریخ انتشار 2002