Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole

نویسندگان

  • Manish Motwani
  • Ananth Kidambi
  • Steven Sourbron
  • Timothy A Fairbairn
  • Akhlaque Uddin
  • Sebastian Kozerke
  • John P Greenwood
  • Sven Plein
چکیده

BACKGROUND Two-dimensional (2D) perfusion cardiovascular magnetic resonance (CMR) remains limited by a lack of complete myocardial coverage. Three-dimensional (3D) perfusion CMR addresses this limitation and has recently been shown to be clinically feasible. However, the feasibility and potential clinical utility of quantitative 3D perfusion measurements, as already shown with 2D-perfusion CMR and positron emission tomography, has yet to be evaluated. The influence of systolic or diastolic acquisition on myocardial blood flow (MBF) estimates, diagnostic accuracy and image quality is also unknown for 3D-perfusion CMR. The purpose of this study was to establish the feasibility of quantitative 3D-perfusion CMR for the detection of coronary artery disease (CAD) and to compare systolic and diastolic estimates of MBF. METHODS Thirty-five patients underwent 3D-perfusion CMR with data acquired at both end-systole and mid-diastole. MBF and myocardial perfusion reserve (MPR) were estimated on a per patient and per territory basis by Fermi-constrained deconvolution. Significant CAD was defined as stenosis ≥70% on quantitative coronary angiography. RESULTS Twenty patients had significant CAD (involving 38 out of 105 territories). Stress MBF and MPR had a high diagnostic accuracy for the detection of CAD in both systole (area under curve [AUC]: 0.95 and 0.92, respectively) and diastole (AUC: 0.95 and 0.94). There were no significant differences in the AUCs between systole and diastole (p values >0.05). At stress, diastolic MBF estimates were significantly greater than systolic estimates (no CAD: 3.21 ± 0.50 vs. 2.75 ± 0.42 ml/g/min, p < 0.0001; CAD: 2.13 ± 0.45 vs. 1.98 ± 0.41 ml/g/min, p < 0.0001); but at rest, there were no significant differences (p values >0.05). Image quality was higher in systole than diastole (median score 3 vs. 2, p = 0.002). CONCLUSIONS Quantitative 3D-perfusion CMR is feasible. Estimates of MBF are significantly different for systole and diastole at stress but diagnostic accuracy to detect CAD is high for both cardiac phases. Better image quality suggests that systolic data acquisition may be preferable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle

BACKGROUND Myocardial blood flow (MBF) varies throughout the cardiac cycle in response to phasic changes in myocardial tension. The aim of this study was to determine if quantitative myocardial perfusion imaging with cardiovascular magnetic resonance (CMR) can accurately track physiological variations in MBF throughout the cardiac cycle. METHODS 30 healthy volunteers underwent a single stress...

متن کامل

Quantitative whole-heart three-dimensional magnetic resonance myocardial perfusion imaging in systole and diastole at 3.0T

Background Two-dimensional (2D) perfusion-CMR has been shown to have greater diagnostic accuracy than single-photon emission computed tomography but remains limited by a lack of complete myocardial coverage. Three-dimensional (3D) whole-heart myocardial perfusion CMR addresses this limitation and has recently been shown to be clinically feasible. However, the feasibility and potential clinical ...

متن کامل

Systolic versus diastolic myocardial blood flow in patients with suspected coronary artery disease - a cardiovascular magnetic resonance study

Background Differences in myocardial blood flow (MBF) between systole and diastole have been reported in healthy volunteers but the impact of cardiac phase on detecting coronary artery disease (CAD) is unknown [1]. This study aimed to compare MBF estimates from cardiovascular magnetic resonance (perfusion-CMR) imaging in systole and diastole in patients with suspected CAD and determine if eithe...

متن کامل

Evaluation of myocardial volume heterogeneity during end-diastole and end-systole using cine MRI.

The aim of this study was to examine the difference in the myocardial volume between end-diastole and end-systole in 24 human volunteers, using steady-state free precession gradient-echo cine imaging of both long- and short-axis views of the left ventricle and a newly developed three-dimensional (3D) analysis method. In addition, we examined retrospectively the cine magnetic resonance imaging (...

متن کامل

Three-dimensional myocardial strains at end-systole and during diastole in the left ventricle of normal humans.

This paper presents the three-dimensional strains in the normal human left ventricle (LV) at end-systole and during diastole. Magnetic resonance tissue tagging was used to measure strain in the left-ventricular heart wall in 10 healthy volunteers aged between 28 and 61 years. The three-dimensional motion was calculated from the displacement of marker points in short- and long-axis cine images, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014