Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters

نویسندگان

  • Ronald A Robinson
  • Luke H Herbertson
  • Srilekha Sarkar Das
  • Richard A Malinauskas
  • William F Pritchard
  • Laurence W Grossman
چکیده

The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Analysis of the Mechanical Properties of a Vena Cava Filter

When anticoagulants are contraindicated for the venous thromboembolism therapy and thromboembolism recurs, a vena cava filter is inserted percutaneously into a major vein in order to prevent blood clots from entering the lungs (Ando & Kuribayashi, 2000; Streiff, 2000) (Fig. 1). The inferior vena cava filter is a mesh structure designed to capture blood clots while not impeding blood flow. This ...

متن کامل

Impact of unilateral common iliac vein occlusion on trapping efficacy of the Greenfield filter: an in vitro study.

RATIONALE AND OBJECTIVES The purpose of this study was to assess the effect of unilateral common iliac vein occlusion on the capturing efficacy of the Greenfield filter in vitro. MATERIALS AND METHODS A stainless steel over-the-wire Greenfield filter was placed in the Silastic inferior vena cava module of a pulsatile circuit. Three 30-mm blood clots in sets of five were injected through the m...

متن کامل

In Silico Evaluation of Local Hemodynamics Following Vena Cava Filter Deployment

Inferior vena cava (IVC) filters have become essential components in deep vein thrombosis treatment, and are particularly critical for preventing pulmonary embolisms in anticoagulation-resistant patients. Filter efficacy relies on maintaining IVC patency, or openness, by preventing filter-induced thrombosis following clot capture. A computational fluid dynamics (CFD) model has been developed to...

متن کامل

Thrombolytic Therapy and Aspiration of Clots were Effective in the Removal of a Transient Inferior Vena Cava (IVC) Filter that Captured a Large Thrombus

A 37-year-old woman presented at 37 weeks of gestation with a history of heaviness in her left leg. Enhanced computed tomography revealed a left extensive ileofemoral thrombus, and we employed a transient inferior vena cava (IVC) filter (t-IVCF) before delivery. Although we attempted to remove the t-IVCF on the day after delivery, a large thrombus was captured in the filter. We therefore perfor...

متن کامل

Training environment for inferior vena caval filter placement.

This paper describes a Virtual Environment system designed to aid in training interventional radiologists in inferior vena cava filter placement. It is being developed as part of a VE simulator for a number of surgical and interventional radiology procedures at the Laboratory for Advanced Computer Applications in Medicine at the George Washington University. In this procedure a filter is placed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013